Electromagnetic and thermal behavior of a single-phase transformer during Ferroresonance considering hysteresis model of core

M Mikhak-Beyranvand, J Faiz, A Rezaei-Zare… - International Journal of …, 2020 - Elsevier
Ferroresonance leads to a high saturation of the transformer core. This causes severe rise of
the amplitude of current and voltage of the transformer and leads to current and voltage non …

Reconstructing primary voltages across inductive VTs—Part I: Methodology

W Sima, B Zou, M Yang, P Duan, Y Zhou… - … on Power Delivery, 2022 - ieeexplore.ieee.org
Inductive voltage transformers (VTs) are the most widely used instrument transformers in
power grids operating at 35 kV and below. Frequently, however, during disturbances, the …

Non‐linear characteristic quantity extraction of ferroresonance overvoltage time series

M Yang, W Sima, Q Yang, J Li, M Zou… - IET Generation …, 2017 - Wiley Online Library
Ferroresonance is a common and complex phenomenon in power systems. Some types of
ferroresonances are remarkably difficult to distinguish from others. This study adopts non …

Smart solid‐state ferroresonance limiter for voltage transformers application: principle and test results

A Heidary, H Radmanesh - IET Power Electronics, 2018 - Wiley Online Library
This study employs a novel smart solid state ferroresonance limiter (SSFL) for stabilising the
chaotic behaviour of a voltage transformer (VT). It is shownthat the ferroresonance …

Suppressing ferroresonance in potential transformers using a model-free active-resistance controller

M Yang, W Sima, L Chen, P Duan, P Sun… - International Journal of …, 2018 - Elsevier
Ferroresonance, excited by saturated electromagnetic voltage transformers, can severely
damage power systems because it produces long duration large overvoltages. In this paper …

Electromagnetic transient study on flexible control processes of ferroresonance

M Yang, W Sima, P Duan, M Zou, D Peng… - International Journal of …, 2017 - Elsevier
Ferroresonance, which is a common phenomenon in power systems, have threatened the
security of power systems for a long time. Although several ferroresonance suppression …

[HTML][HTML] Non-Contact Adaptive Voltage Sensor Based on Electric Field Coupling Principle

X Tan, W Zhang, M He, W Li, G Ao, F Zhou - Sensors, 2023 - mdpi.com
Non-contact voltage sensors based on the principle of electric field coupling have the
advantages of simple loading and unloading, high construction safety, and the fact that they …

Accurate simulation model for a three-phase ferroresonant circuit in EMTP–ATP

M Zou - International Journal of Electrical Power & Energy …, 2019 - Elsevier
This study presents a simulation model for a ferroresonant circuit. The proposed model
includes a transformer model and a vacuum circuit breaker (VCB) model. Hysteresis …

Electronic resistor emulators for ferroresonance dam** in MV transformers

E Bayona, F Azcondo, C Brañas, J Diaz… - IET Renewable …, 2019 - Wiley Online Library
The occurrence of ferroresonances, due to the presence of voltage transformers in isolated‐
neutral in medium‐voltage (MV) distribution grids, results in overvoltages and overcurrents …

[PDF][PDF] Conversion of RMS into instantaneous transformer saturation characteristics–implementation in MATLAB/SPS-ST

A Tokić, V Milardić, M Kasumović… - International review of …, 2019 - researchgate.net
The paper presents a reduced form of the algorithm for converting a measured RMS
transformer characteristic into the corresponding peak instantaneous transformer saturation …