Impedance and noise of passive and active dry EEG electrodes: a review

EHT Shad, M Molinas, T Ytterdal - IEEE Sensors Journal, 2020 - ieeexplore.ieee.org
Dry electrodes are a promising solution for prolonged EEG signal acquisition, whereas wet
electrodes may lose their signal quality in the same situation and require skin preparation for …

Closed-loop neural prostheses with on-chip intelligence: A review and a low-latency machine learning model for brain state detection

B Zhu, U Shin, M Shoaran - IEEE transactions on biomedical …, 2021 - ieeexplore.ieee.org
The application of closed-loop approaches in systems neuroscience and therapeutic
stimulation holds great promise for revolutionizing our understanding of the brain and for …

NeuralTree: A 256-channel 0.227-μJ/class versatile neural activity classification and closed-loop neuromodulation SoC

U Shin, C Ding, B Zhu, Y Vyza… - IEEE Journal of Solid …, 2022 - ieeexplore.ieee.org
Closed-loop neural interfaces with on-chip machine learning can detect and suppress
disease symptoms in neurological disorders or restore lost functions in paralyzed patients …

A wearable platform for closed-loop stimulation and recording of single-neuron and local field potential activity in freely moving humans

U Topalovic, S Barclay, C Ling, A Alzuhair, W Yu… - Nature …, 2023 - nature.com
Advances in technologies that can record and stimulate deep brain activity in humans have
led to impactful discoveries within the field of neuroscience and contributed to the …

A 15.2-ENOB 5-kHz BW 4.5- W Chopped CT -ADC for Artifact-Tolerant Neural Recording Front Ends

H Chandrakumar, D Marković - IEEE Journal of Solid-State …, 2018 - ieeexplore.ieee.org
Implantable closed-loop neural stimulation is desirable for clinical translation and basic
neuroscience research. Neural stimulation generates large artifacts at the recording sites …

A closed-loop neuromodulation chipset with 2-level classification achieving 1.5-Vpp CM interference tolerance, 35-dB stimulation artifact rejection in 0.5 ms and 97.8 …

Y Wang, H Luo, Y Chen, Z Jiao, Q Sun… - … Circuits and Systems, 2021 - ieeexplore.ieee.org
This work presents an 8-channel closed-loop neuromodulation chipset with 2-level seizure
classification. The power-consuming fine classifier is only enabled when the coarse …

Power-saving design opportunities for wireless intracortical brain–computer interfaces

N Even-Chen, DG Muratore, SD Stavisky… - Nature biomedical …, 2020 - nature.com
The efficacy of wireless intracortical brain–computer interfaces (iBCIs) is limited in part by
the number of recording channels, which is constrained by the power budget of the …

A low-noise chopper amplifier designed for multi-channel neural signal acquisition

D Luo, M Zhang, Z Wang - IEEE Journal of Solid-State Circuits, 2019 - ieeexplore.ieee.org
This paper proposed the design of a low-noise, low total harmonic distortion (THD) chopper
amplifier for neural signal acquisition. A dc servo loop (DSL) based on active Gm-C …

A single-chip bidirectional neural interface with high-voltage stimulation and adaptive artifact cancellation in standard CMOS

JP Uehlin, WA Smith, VR Pamula… - IEEE Journal of Solid …, 2020 - ieeexplore.ieee.org
A single-chip, bidirectional brain-computer interface (BBCI) enables neuromodulation
through simultaneous neural recording and stimulation. This article presents a prototype …

A 13.9-na ecg amplifier achieving 0.86/0.99 nef/pef using ac-coupled ota-stacking

S Mondal, DA Hall - IEEE Journal of Solid-State Circuits, 2019 - ieeexplore.ieee.org
An ultra-low power electrocardiogram (ECG) recording front-end intended for implantable
sensors is presented. The noise-limited, high power first stage of a two-stage amplifier …