Pollution flashover voltage of transmission line insulators: Systematic review of experimental works
Over the past decades, extensive experimental-based research works have been carried out
to investigate the flashover phenomenon on the performance of polluted transmission line …
to investigate the flashover phenomenon on the performance of polluted transmission line …
Aging of polymeric insulators under various conditions and environments: Another look
Polymeric insulators have lightweight, excellent hydrophobicity and convenient
transportation and installation. They are widely used in the external insulation for distribution …
transportation and installation. They are widely used in the external insulation for distribution …
Influence of pollution on surface streamer discharge
The outdoor insulators in the transmission lines are apt to accumulate pollution on the
surface in the atmospheric environment. The pollution flashover is liable to occur after the …
surface in the atmospheric environment. The pollution flashover is liable to occur after the …
Influence of contaminated location on streamer discharge
Pollution flashover along the insulator is a common accident in power systems with severe
impacts. Researchers have conducted many studies on the external characteristics of …
impacts. Researchers have conducted many studies on the external characteristics of …
Application of hydrophobic coating to reduce leakage current through surface energy control of high voltage insulator
T Kim, J Yi - Applied Surface Science, 2022 - Elsevier
A hydrophobic coating was applied using atmospheric-pressure plasma to solve the
problem of leakage current caused by the attachment of pollutants to transmission line …
problem of leakage current caused by the attachment of pollutants to transmission line …
Electric Field Distribution and AC Breakdown Characteristics of Polluted Novel Lightning Protection Insulator under Icing Conditions
J Lu, J Hu, Z Fang, X Qiao, Z Zhang - Energies, 2021 - mdpi.com
As a result of lightning strikes, pollution, and ice, overhead distribution wires might be short-
circuited and trip. As a result, researchers have developed a new lightning protection …
circuited and trip. As a result, researchers have developed a new lightning protection …
Study on the frequency and temperature dependence of electrical conductivity of zinc oxide valve plate
T Fuqiang, T Yonghuan, W Jiabao… - … on Dielectrics and …, 2023 - ieeexplore.ieee.org
Under the action of overvoltage and harmonic voltage, the onboard zinc oxide arrester of
electric motor units (EMUs) will affect its action characteristics due to heating. In this article …
electric motor units (EMUs) will affect its action characteristics due to heating. In this article …
An experimental study of the flashover performances of outdoor high-voltage polymeric insulators under fan-shaped pollution and dry band location
The rise in transmission line voltage has significantly raised the importance of insulator
contamination studies to understand the physical principles governing this occurrence and …
contamination studies to understand the physical principles governing this occurrence and …
Characteristics of streamer discharge along the insulation surface with embedded electrode
X Meng, L Lin, H Li, Y Chen… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Surface discharge was a common accident in power systems, significantly impacting the
safe and stable operation of the power grid. The insulation structure of power equipment …
safe and stable operation of the power grid. The insulation structure of power equipment …
[PDF][PDF] 10 kV 复合避雷器组合绝缘子雷电冲击污闪特性及模型
乔新涵, 张志劲, 蒋**龙, 蒋兴良… - 电工技术学报, 2024 - dgjsxb.ces-transaction.com
摘要雷击与污秽会威胁电网安全稳定运行, 因此, 该文对具有雷电防护功能的复合避雷器组合
绝缘子的冲击污闪模型进行了研究. 首先, 分析了适用于组合绝缘子的冲击电压闪络模型; 其次 …
绝缘子的冲击污闪模型进行了研究. 首先, 分析了适用于组合绝缘子的冲击电压闪络模型; 其次 …