Model-based image reconstruction for MRI

JA Fessler - IEEE signal processing magazine, 2010 - ieeexplore.ieee.org
Magnetic resonance imaging (MRI) is a sophisticated and versatile medical imaging
modality. The inverse FFT has served the MR community very well as the conventional …

Artificial intelligence-based image enhancement in pet imaging: Noise reduction and resolution enhancement

J Liu, M Malekzadeh, N Mirian, TA Song, C Liu… - PET clinics, 2021 - pet.theclinics.com
PET is a noninvasive molecular imaging modality that is increasingly popular in oncology,
neurology, cardiology, and other fields. 1–3 Accurate quantitation of PET radiotracer uptake …

Digimouse: a 3D whole body mouse atlas from CT and cryosection data

B Dogdas, D Stout, AF Chatziioannou… - Physics in Medicine & …, 2007 - iopscience.iop.org
We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-
ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and …

[PDF][PDF] Statistical image reconstruction methods for transmission tomography

JA Fessler, M Sonka, JM Fitzpatrick - Handbook of medical imaging, 2000 - eecs.umich.edu
The problem of forming cross-sectional or tomographic images of the attenuation
characteristics of objects arises in a variety of contexts, including medical X-ray computed …

Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner

Y Wang, J Seidel, BMW Tsui, JJ Vaquero… - Journal of Nuclear …, 2006 - Soc Nuclear Med
We evaluated the performance characteristics of the eXplore VISTA dual-ring small-animal
PET scanner, a stationary, ring-type, depth-of-interaction (DOI) correcting system designed …

Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET

S Ahn, SG Ross, E Asma, J Miao, X **… - Physics in Medicine …, 2015 - iopscience.iop.org
Ordered subset expectation maximization (OSEM) is the most widely used algorithm for
clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control …

Non-local means denoising of dynamic PET images

J Dutta, RM Leahy, Q Li - PloS one, 2013 - journals.plos.org
Objective Dynamic positron emission tomography (PET), which reveals information about
both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative …

Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation

S Tong, AM Alessio, PE Kinahan - Physics in Medicine & Biology, 2010 - iopscience.iop.org
The addition of accurate system modeling in PET image reconstruction results in images
with distinct noise texture and characteristics. In particular, the incorporation of point spread …

MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging

YC Tai, AF Chatziioannou, Y Yang… - Physics in medicine …, 2003 - iopscience.iop.org
MicroPET II is a second-generation animal PET scanner designed for high-resolution
imaging of small laboratory rodents. The system consists of 90 scintillation detector modules …

Overview of methods for image reconstruction from projections in emission computed tomography

RM Lewitt, S Matej - Proceedings of the IEEE, 2003 - ieeexplore.ieee.org
Emission computed tomography (ECT) is a technology for medical imaging whose
importance is increasing rapidly. There is a growing appreciation for the value of the …