Model-based image reconstruction for MRI
JA Fessler - IEEE signal processing magazine, 2010 - ieeexplore.ieee.org
Magnetic resonance imaging (MRI) is a sophisticated and versatile medical imaging
modality. The inverse FFT has served the MR community very well as the conventional …
modality. The inverse FFT has served the MR community very well as the conventional …
Artificial intelligence-based image enhancement in pet imaging: Noise reduction and resolution enhancement
PET is a noninvasive molecular imaging modality that is increasingly popular in oncology,
neurology, cardiology, and other fields. 1–3 Accurate quantitation of PET radiotracer uptake …
neurology, cardiology, and other fields. 1–3 Accurate quantitation of PET radiotracer uptake …
Digimouse: a 3D whole body mouse atlas from CT and cryosection data
We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-
ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and …
ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and …
[PDF][PDF] Statistical image reconstruction methods for transmission tomography
The problem of forming cross-sectional or tomographic images of the attenuation
characteristics of objects arises in a variety of contexts, including medical X-ray computed …
characteristics of objects arises in a variety of contexts, including medical X-ray computed …
Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner
We evaluated the performance characteristics of the eXplore VISTA dual-ring small-animal
PET scanner, a stationary, ring-type, depth-of-interaction (DOI) correcting system designed …
PET scanner, a stationary, ring-type, depth-of-interaction (DOI) correcting system designed …
Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET
Ordered subset expectation maximization (OSEM) is the most widely used algorithm for
clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control …
clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control …
Non-local means denoising of dynamic PET images
Objective Dynamic positron emission tomography (PET), which reveals information about
both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative …
both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative …
Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation
The addition of accurate system modeling in PET image reconstruction results in images
with distinct noise texture and characteristics. In particular, the incorporation of point spread …
with distinct noise texture and characteristics. In particular, the incorporation of point spread …
MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging
MicroPET II is a second-generation animal PET scanner designed for high-resolution
imaging of small laboratory rodents. The system consists of 90 scintillation detector modules …
imaging of small laboratory rodents. The system consists of 90 scintillation detector modules …
Overview of methods for image reconstruction from projections in emission computed tomography
RM Lewitt, S Matej - Proceedings of the IEEE, 2003 - ieeexplore.ieee.org
Emission computed tomography (ECT) is a technology for medical imaging whose
importance is increasing rapidly. There is a growing appreciation for the value of the …
importance is increasing rapidly. There is a growing appreciation for the value of the …