[HTML][HTML] Temporary mechanical circulatory support in acute heart failure

F Jiritano, VL Coco, M Matteucci, D Fina… - Cardiac Failure …, 2020 - ncbi.nlm.nih.gov
Cardiogenic shock (CS) is a challenging syndrome, associated with significant morbidity
and mortality. Although pharmacological therapies are successful and can successfully …

A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient‐specific aortic …

MV Caruso, V Gramigna, M Rossi… - … journal for numerical …, 2015 - Wiley Online Library
Left ventricular assist devices (LVADs) are mechanical supports used in case of heart
failure. Little is known as the height of the anastomosis in aorta might influence the …

Numerical prediction of the effect of aortic Left Ventricular Assist Device outflow-graft anastomosis location

R Mazzitelli, F Boyle, E Murphy, A Renzulli… - Biocybernetics and …, 2016 - Elsevier
Abstract A Left Ventricular Assist Device (LVAD) is used to provide haemodynamic support
to patients with critical cardiac failure. As LVADs generate continuous flow to better …

Numerical analysis of aortic hemodynamics under the support of venoarterial extracorporeal membrane oxygenation and intra-aortic balloon pump

K Gu, Z Guan, X Lin, Y Feng, J Feng, Y Yang… - Computer Methods and …, 2019 - Elsevier
Background and objective A gap still exists in the hemodynamic effect of intra-aortic balloon
pump (IABP), venoarterial extracorporeal membrane oxygenation (VA-ECMO), and VA …

Modification of Poiseuille Flow to a Pulsating Flow Using a Periodically Expanding-Contracting Balloon

I Moulinos, C Manopoulos, S Tsangaris - Fluids, 2023 - mdpi.com
Balloon pumps are employed to assist cardiac function in cases of acute myocardial
infarction, ventricular arrhythmias, cardiogenic shock, unstable angina, refractory ventricular …

Effects of a short-term left ventricular assist device on hemodynamics in a heart failure patient-specific aorta model: a CFD study

Y Wang, J Wang, J Peng, M Huo, Z Yang… - Frontiers in …, 2021 - frontiersin.org
Patients with heart failure (HF) or undergoing cardiogenic shock and percutaneous coronary
intervention require short-term cardiac support. Short-term cardiac support using a left …

Hemodynamic Evaluation of Intra‐Aortic Dual‐Balloon Pump Based on Fluid–Structure Interaction

H Ma, Y Wang, B Gao, S Li, Z Song… - International Journal …, 2025 - Wiley Online Library
The intra‐aortic balloon pump (IABP) is a widely‐used mechanical circulatory support
device that enhances hemodynamics in patients with heart conditions. Although the IABP is …

Different blood flow models in coronary artery diseases: effects on hemodynamic parameters

LT Gaudio, MV Caruso, S De Rosa… - 2018 40th Annual …, 2018 - ieeexplore.ieee.org
Coronary arteries are medium-small caliber vessels, in which low shear rate values are
encountered, where non-Newtonian blood effects cannot be neglected. This work aims to …

Design and evaluation of an air-insulated catheter for intra-arterial selective cooling infusion from numerical simulation and in vitro experiment

M Jiang, M Li, Y Gao, Z Yin, Y Ding, Y Zheng… - Medical Engineering & …, 2022 - Elsevier
Intra-arterial selective cooling infusion (IA-SCI) is a promising method for neuroprotection of
patients with acute ischemic stroke. One shortcoming of IA-SCI is the elevated delivery …

Influence of aortic outflow cannula orientation on epiaortic flow pattern during pulsed cardiopulmonary bypass

MV Caruso, V Gramigna, GF Serraino… - Journal of Medical and …, 2015 - Springer
Cerebral hypoperfusion that may occur during linear cardiopulmonary bypass (CPB) is often
responsible for mnemonic problems, loss of neural functions, or coma. Pulsed CPB might …