Capability of synchronous and asynchronous hydropower generating systems: A comprehensive study

K Subramanya, TR Chelliah - Renewable and Sustainable Energy …, 2023 - Elsevier
Hydropower is the third largest supplier of global electricity generation trailing behind coal
and natural gas. It serves as the backbone of low-carbon electricity generation, supplying …

Grid ancillary services from doubly fed induction generator-based wind energy conversion system: A review

M Debouza, A Al-Durra - IEEE Access, 2018 - ieeexplore.ieee.org
Modern electrical grids face serious challenges to maintain healthy operational conditions.
The nominal voltage and frequency, for instance, are affected by huge load changes and …

Combined resonant controller and two-degree-of-freedom PID controller for PMSLM current harmonics suppression

Z Pan, F Dong, J Zhao, L Wang… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
This paper presents a new control method to suppress current harmonics for permanent
magnet synchronous linear motor (PMSLM) that is applied in the miniature microsecond …

Feedforward current references control for DFIG-based wind turbine to improve transient control performance during grid faults

D Zhu, X Zou, S Zhou, W Dong… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
For doubly fed induction generator (DFIG) based wind turbines, when severe grid faults
occur, it is necessary to inject transient and negative-sequence components into the rotor …

A microgrid based on wind-driven DFIG, DG, and solar PV array for optimal fuel consumption

S Puchalapalli, SK Tiwari, B Singh… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
This article presents a green energy solution to a microgrid for a location dependent on a
diesel generator (DG) to meet its electricity requirement. This microgrid is powered by two …

Analysis and resha** on impedance characteristic of DFIG system based on symmetrical PLL

H Nian, B Hu, Y Xu, C Wu, L Chen… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
With the increasing penetration of renewable energy, wind turbines based on doubly fed
induction generators (DFIG) are becoming more and more important in the power system …

Enhanced position sensorless control using bilinear recursive least squares adaptive filter for interior permanent magnet synchronous motor

X Wu, S Huang, K Liu, K Lu, Y Hu… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
In the back electromotive force (EMF)-based sensorless control of interior permanent
magnet synchronous motor (IPMSM), the inverter nonlinearity and flux linkage spatial …

A novel control scheme for wind turbine driven DFIG interfaced to utility grid

S Puchalapalli, B Singh - IEEE Transactions on Industry …, 2020 - ieeexplore.ieee.org
This article deals with a phase-locked loop (PLL)-based novel control for wind turbine driven
doubly fed induction generator interfaced to utility grid with a battery energy storage (BES) …

High-frequency resonance analysis and resha** control strategy of DFIG system based on DPC

B Hu, H Nian, J Yang, M Li, Y Xu - IEEE Transactions on Power …, 2020 - ieeexplore.ieee.org
Direct power control (DPC) can reduce the complexity of a controller and enhance the
dynamic response for doubly fed induction generators (DFIG) system. The high-frequency …

Analysis of high-frequency resonance in DFIG-based offshore wind farm via long transmission cable

Y Song, E Ebrahimzadeh… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
During the past two decades, the doubly fed induction generator (DFIG) based wind farm
has been under rapid growth, and the increasing wind power penetration has been seen …