Noninvasive internal body temperature tracking with near-field microwave radiometry

P Momenroodaki, W Haines… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
This paper presents a study of near-field radiometry for internal temperature measurements
of the human body. The radiometer has a Dicke architecture and operates in the 1.4-GHz …

Imaging-based internal body temperature measurements: The journal Temperature toolbox

J Raiko, K Koskensalo, T Sainio - Temperature, 2020 - Taylor & Francis
Noninvasive imaging methods of internal body temperature are in high demand in both
clinical medicine and physiological research. Thermography and thermometry can be used …

Thermal dosimetry for bladder hyperthermia treatment. An overview

G Schooneveldt, A Bakker, E Balidemaj… - International Journal …, 2016 - Taylor & Francis
The urinary bladder is a fluid-filled organ. This makes, on the one hand, the internal surface
of the bladder wall relatively easy to heat and ensures in most cases a relatively …

Design and optimization of an ultra wideband and compact microwave antenna for radiometric monitoring of brain temperature

DB Rodrigues, PF Maccarini, S Salahi… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
We present the modeling efforts on antenna design and frequency selection to monitor brain
temperature during prolonged surgery using noninvasive microwave radiometry. A tapered …

Non-invasive measurement of brain temperature with microwave radiometry: demonstration in a head phantom and clinical case

PR Stauffer, BW Snow, DB Rodrigues… - The …, 2014 - journals.sagepub.com
This study characterizes the sensitivity and accuracy of a non-invasive microwave
radiometric thermometer intended for monitoring body core temperature directly in brain to …

Design and interdisciplinary simulations of a hand-held device for internal-body temperature sensing using microwave radiometry

NA Livanos, S Hammal, CD Nikolopoulos… - IEEE Sensors …, 2018 - ieeexplore.ieee.org
The development of contemporary complex technological systems prerequisites
interdisciplinary design and simulation methodologies. Such an approach is demonstrated …

Radiometric analysis of ankle edema via RZF antenna for biomedical applications

GP Ramesh, N Mohan Kumar - Wireless Personal Communications, 2018 - Springer
In this paper, diabetic measure via non-invasive technique form the peripheral edema is
proposed. The peripheral edema arises in the diabetic person in the ankle with thick skin …

A 3.5-GHz pseudo-correlation type radiometer for biomedical applications

E Villa, N Arteaga-Marrero, G León, LF Herrán… - … -International Journal of …, 2021 - Elsevier
A pseudo-correlation type radiometer based on astrophysical instrumentation is proposed
for biomedical applications. The working frequency band is centred at 3.5 GHz. The …

A 1.4-GHz radiometer for internal body temperature measurements

P Momenroodaki, Z Popovic… - 2015 European …, 2015 - ieeexplore.ieee.org
This paper presents a 1.4-GHz microwave radiometer for noninvasive measurements of
internal (core) body temperature. The 1.4 GHz frequency of operation is chosen for deep cm …

Microwave radiometry for noninvasive monitoring of brain temperature

DB Rodrigues, PR Stauffer, PJS Pereira… - … technologies for brain …, 2018 - Springer
Microwave radiometry is a passive and noninvasive technique that is able to measure deep
tissue temperature and track changes in thermal profiles in tissue up to 5 cm below the …