Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Report of AAPM task group 235 radiochromic film dosimetry: an update to TG‐55
A Niroomand‐Rad, ST Chiu‐Tsao, MP Grams… - Medical …, 2020 - Wiley Online Library
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high
level of achievable accuracy for a wide range of dose values and its suitability under a …
level of achievable accuracy for a wide range of dose values and its suitability under a …
Small-field radiotherapy photon beam output evaluation: Detectors reviewed
Small fields (few cm and below) are being applied in therapy independently or as mm/sub-
cm segments of larger fields. Included are intensity modulated radiotherapy …
cm segments of larger fields. Included are intensity modulated radiotherapy …
Characterization of an enhanced formulation N-(3-methoxypropyl) acrylamide polymer gel dosimeter by the addition of an organic sensitizer for clinical practice
Polymer gel dosimeters are being developed and improved to perform measurements of
radiation dose distributions in 3-dimensions (3-D) for the purpose of patient specific quality …
radiation dose distributions in 3-dimensions (3-D) for the purpose of patient specific quality …
Dosimetry of cone‐defined stereotactic radiosurgery fields with a commercial synthetic diamond detector
Purpose: Small field x‐ray beam dosimetry is difficult due to lack of lateral electronic
equilibrium, source occlusion, high dose gradients, and detector volume averaging …
equilibrium, source occlusion, high dose gradients, and detector volume averaging …
Improvement on the performance of chemically cross-linked fricke methylthymol-blue radiochromic gel dosimeter by addition of dimethyl sulfoxide
The effect of free radical scavenger dimethyl sulfoxide (DMSO) on the performance of
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
Characterization of ferrous-methylthymol blue-polyvinyl alcohol gel dosimeters using nuclear magnetic resonance and optical techniques
A new composition of Ferrous sulphate-Metheylthymol blue (MTB)-Polyvinyl alcohol (PVA)
dosimeter is introduced in this work and evaluated using nuclear magnetic resonance …
dosimeter is introduced in this work and evaluated using nuclear magnetic resonance …
Evaluation of ferrous Methylthymol blue gelatin gel dosimeters using nuclear magnetic resonance and optical techniques
Signal development of irradiated Methylthymol blue (MTB) Fricke gelatin gel dosimeter was
studied using nuclear magnetic resonance (NMR) in terms of the spin-spin relaxation rate (R …
studied using nuclear magnetic resonance (NMR) in terms of the spin-spin relaxation rate (R …
Optical characterization of Fricke-methylthymol blue hydrogel dosimeter with gellan gum as physical cross-linker
Modified formulation radio-chromic dosimeter consists of Fricke polyvinyl alcohol (PVA) with
Methylthymol blue dye (MTB) and physical cross-linking agent gellan gum (GG) was …
Methylthymol blue dye (MTB) and physical cross-linking agent gellan gum (GG) was …
An experimental extrapolation technique using the Gafchromic EBT3 film for relative output factor measurements in small x‐ray fields
Purpose: An experimental extrapolation technique is presented, which can be used to
determine the relative output factors for very small x‐ray fields using the Gafchromic EBT3 …
determine the relative output factors for very small x‐ray fields using the Gafchromic EBT3 …
Nuclear magnetic resonance analysis of a chemically cross-linked ferrous–methylthymol blue–polyvinyl alcohol radiochromic gel dosimeter
A new formulation of hydrogel dosimeter consisting of ferrous–methylthymol blue (MTB)–
polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and …
polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and …