Security of wide-area monitoring, protection, and control (WAMPAC) systems of the smart grid: A survey on challenges and opportunities
The evolution of power generation systems, along with their related increase in complexity,
led to the critical necessity of Wide-Area Monitoring, Protection, and Control (WAMPAC) …
led to the critical necessity of Wide-Area Monitoring, Protection, and Control (WAMPAC) …
Impact, vulnerabilities, and mitigation strategies for cyber-secure critical infrastructure
Several critical infrastructures are integrating information technology into their operations,
and as a result, the cyber attack surface extends over a broad range of these infrastructures …
and as a result, the cyber attack surface extends over a broad range of these infrastructures …
Smart substation communications and cybersecurity: A comprehensive survey
Electrical grids generate, transport, distribute and deliver electrical power to consumers
through a complex Critical Infrastructure which progressively shifted from an air-gaped to a …
through a complex Critical Infrastructure which progressively shifted from an air-gaped to a …
A comprehensive survey on phasor measurement unit applications in distribution systems
Synchrophasor technology opens a new window for power system observability. Phasor
measurement units (PMUs) are able to provide synchronized and accurate data such as …
measurement units (PMUs) are able to provide synchronized and accurate data such as …
Research trends and applications of PMUs
This work is a survey of current trends in applications of PMUs. PMUs have the potential to
solve major problems in the areas of power system estimation, protection, and stability. A …
solve major problems in the areas of power system estimation, protection, and stability. A …
Real-Time Synchrophasor Data Anomaly Detection and Classification Using Isolation Forest, KMeans, and LoOP
Power grid operators assess situational awareness using time-tagged measurements from
phasor measurement units (PMUs) placed at multiple locations in a network. However …
phasor measurement units (PMUs) placed at multiple locations in a network. However …
Frequency injection based HVDC attack-defense control via squeeze-excitation double CNN
Due to the independent controllability and fast power regulation capability, the High Voltage
Direct Current (HVDC) system could be a prospective technology to provide multiple …
Direct Current (HVDC) system could be a prospective technology to provide multiple …
Current differential protection for active distribution networks based on improved fault data self-synchronization method
C Zhou, G Zou, L Zang, X Du - IEEE Transactions on Smart Grid, 2021 - ieeexplore.ieee.org
The uncertainty in the direction and magnitude of fault current is a thorny issue for active
distribution network (ADN) protection. Current differential protection (CDP) is suitable for …
distribution network (ADN) protection. Current differential protection (CDP) is suitable for …
Artificial intelligence techniques for power system transient stability assessment
The high penetration of renewable energy sources, coupled with decommissioning of
conventional power plants, leads to the reduction of power system inertia. This has negative …
conventional power plants, leads to the reduction of power system inertia. This has negative …
DPMU-based multiple event detection in a microgrid considering measurement anomalies
A microgrid may be subjected to various unexpected events, such as sudden trip** of a
generator/load, line outages due to faults, sudden switching of large capacitor banks, etc …
generator/load, line outages due to faults, sudden switching of large capacitor banks, etc …