Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

S Biricik, S Redif, ÖC Özerdem… - IET Power …, 2014 - Wiley Online Library
In this paper, an alternative control method is proposed to improve the harmonic
suppression efficiency of the active power filter in a distorted and an unbalanced power …

Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction

Y Hoon, MAM Radzi, MK Hassan… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, a new reference current generation method is proposed for effective harmonics
mitigation and reactive power compensation of three-level neutral-point diode clamped …

An HIL-based reconfigurable platform for design, implementation, and verification of electrical system digital controllers

S Karimi, P Poure, S Saadate - IEEE Transactions on Industrial …, 2009 - ieeexplore.ieee.org
This paper presents a top-down design flow for design, implementation, and verification of
digital controllers associated with electrical systems. In the proposed design flow, the …

A novel strategy for shunt active filter control

A Boussaid, AL Nemmour, L Louze… - Electric Power Systems …, 2015 - Elsevier
The present paper proposes the use of an advanced algorithm based on the instantaneous
powers theory for harmonics current compensation. A fast and exact computation of …

A dual fundamental current extraction controller for DSTATCOM in the distribution system for power quality improvement under non-ideal source voltage condition

A Ram, PR Sharma, RK Ahuja… - … Power Components and …, 2023 - Taylor & Francis
Most of the controllers often fail to work properly when encountered with power quality (PQ)
issues like unbalanced and distorted grid voltage conditions in three-phase distribution …

Adaptive notch filter solution under unbalanced and/or distorted point of common coupling voltage for three‐phase four‐wire shunt active power filter with sinusoidal …

ND Dinh, ND Tuyen, G Fujita… - IET Generation …, 2015 - Wiley Online Library
In this study, the three‐phase four‐wire shunt active power filter (ShAPF) dealing with non‐
ideal point of common coupling (PCC) voltages will be presented. The instantaneous power …

Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems

S Biricik, S Redif, SK Khadem… - International Journal of …, 2016 - Taylor & Francis
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single-phase active power filter in a distorted power system to suppress current …

A modified IRPT control method for a shunt active power filter for unbalanced conditions

S Al-Gahtani, RM Nelms - 2019 IEEE 28th international …, 2019 - ieeexplore.ieee.org
The presence of power electronics devices on the power grid can cause power quality
problems such as harmonic distortion and power system unbalance. Shunt active power …

[PDF][PDF] PV based three-level NPC shunt active power filter with extended reference current generation method

M Vijayakumar, S Vijayan - International Journal of Electrical Energy, 2014 - ijoee.org
This paper proposes an extended reference current calculation method for the PV based
three-level neutral point clamped (NPC) shunt active power filter (SAPF). Shunt active power …

Control of the shunt active power filter under non-ideal grid voltage and unbalanced load conditions

S Biricik, S Redif, OC Ozerdem… - 2013 48th International …, 2013 - ieeexplore.ieee.org
In this study a new method is proposed in order to improve the harmonic suppression
efficiency of Active Power Filter for the problems caused by the distorted and unbalanced …