[HTML][HTML] Transport of intensity equation: a tutorial
When it comes to “phase measurement” or “quantitative phase imaging”, many people will
automatically connect them with “laser” and “interferometry”. Indeed, conventional …
automatically connect them with “laser” and “interferometry”. Indeed, conventional …
One-step robust deep learning phase unwrap**
Phase unwrap** is an important but challenging issue in phase measurement. Even with
the research efforts of a few decades, unfortunately, the problem remains not well solved …
the research efforts of a few decades, unfortunately, the problem remains not well solved …
High-resolution transport-of-intensity quantitative phase microscopy with annular illumination
For quantitative phase imaging (QPI) based on transport-of-intensity equation (TIE), partially
coherent illumination provides speckle-free imaging, compatibility with brightfield …
coherent illumination provides speckle-free imaging, compatibility with brightfield …
Computational illumination for high-speed in vitro Fourier ptychographic microscopy
We demonstrate a new computational illumination technique that achieves a large space–
bandwidth–time product, for quantitative phase imaging of unstained live samples in vitro …
bandwidth–time product, for quantitative phase imaging of unstained live samples in vitro …
Deep phase decoder: self-calibrating phase microscopy with an untrained deep neural network
Deep neural networks have emerged as effective tools for computational imaging, including
quantitative phase microscopy of transparent samples. To reconstruct phase from intensity …
quantitative phase microscopy of transparent samples. To reconstruct phase from intensity …
3D differential phase contrast microscopy
We demonstrate 3D phase and absorption recovery from partially coherent intensity images
captured with a programmable LED array source. Images are captured through-focus with …
captured with a programmable LED array source. Images are captured through-focus with …
Varifocal metalens for compact and accurate quantitative phase imaging
The transport of intensity equation (TIE), a noninterferometric method for quantitative phase
imaging (QPI), enables the characterization of transparent objects and is widely applied in …
imaging (QPI), enables the characterization of transparent objects and is widely applied in …
Quantitative phase imaging endoscopy with a metalens
Quantitative phase imaging (QPI) recovers the exact wavefront of light from intensity
measurements. Topographical and optical density maps of translucent microscopic bodies …
measurements. Topographical and optical density maps of translucent microscopic bodies …
Fast and accurate phase-unwrap** algorithm based on the transport of intensity equation
The phase information of a complex field is routinely obtained using coherent measurement
techniques as, eg, interferometry or holography. The obtained measurement result is subject …
techniques as, eg, interferometry or holography. The obtained measurement result is subject …
Smartphone based hand-held quantitative phase microscope using the transport of intensity equation method
In order to realize high contrast imaging with portable devices for potential mobile
healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope …