Metascintillators for ultrafast gamma detectors: A review of current state and future perspectives
Scintillation detector development is an active field of research, especially for its application
to the medical imaging field and in particular to the positron emission tomography (PET) …
to the medical imaging field and in particular to the positron emission tomography (PET) …
A comprehensive survey of readout strategies for SiPMs used in nuclear imaging systems
Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size,
and lower operating voltages compared to photomultiplier tubes. A SiPM's readout circuit …
and lower operating voltages compared to photomultiplier tubes. A SiPM's readout circuit …
DOI estimation through signal arrival time distribution: a theoretical description including proof of concept measurements
The challenge to reach 10 ps coincidence time resolution (CTR) in time-of-flight positron
emission tomography (TOF-PET) is triggering major efforts worldwide, but timing …
emission tomography (TOF-PET) is triggering major efforts worldwide, but timing …
Development and evaluation of 0.35-mm-pitch PET detectors with different reflector arrangements
The spatial resolutions of preclinical positron emission tomography (PET) imagers are
largely determined by the size of the crystals. This study explores methods to construct PET …
largely determined by the size of the crystals. This study explores methods to construct PET …
Simultaneous time-skew and time-walk correction for TOF-PET detector
E Yoshida, F Obata, T Yamaya - … and Methods in Physics Research Section …, 2023 - Elsevier
Abstract Time-of-flight (TOF) has become a very important technology in PET, as it reduces
noise to improve the PET imaging performance significantly. To obtain a high coincidence …
noise to improve the PET imaging performance significantly. To obtain a high coincidence …
Experimental validation of a coincidence time resolution metric including depth-of-interaction bias for TOF-PET
Abstract Depth-of-interaction (DOI) variability of annihilation photons is known to be a source
of coincidence time resolution (CTR) degradation for fast time-of-flight–positron emission …
of coincidence time resolution (CTR) degradation for fast time-of-flight–positron emission …
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction
(DOI) for positron emission tomography (PET) detectors. In the present study, the effects of …
(DOI) for positron emission tomography (PET) detectors. In the present study, the effects of …
A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors
Positron emission tomography (PET) detectors suffer from time-walk when the leading edge
discriminator is employed for timing pick-off as well as a timing-shift when thick crystals are …
discriminator is employed for timing pick-off as well as a timing-shift when thick crystals are …
[КНИГА][B] Precise Pulse Discrimination for Space-Based Timing Front Ends
L Lee - 2023 - search.proquest.com
The conversion of trigger events to their digital equivalent is a central component of any
timing-based front end, with applications found in mass spectrometry, single channel …
timing-based front end, with applications found in mass spectrometry, single channel …
A time-based single transmission-line readout with position multiplexing
We developed a time-based single-transmission-line readout method for time-of-flight
positron emission tomography (PET) detectors. The 2D position of a silicon photomultiplier …
positron emission tomography (PET) detectors. The 2D position of a silicon photomultiplier …