X-ray phase-contrast imaging

M Endrizzi - Nuclear instruments and methods in physics research …, 2018 - Elsevier
X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of
samples. It finds application in a vast diversity of fields: medicine, biology, many engineering …

Edge-illumination x-ray phase-contrast imaging

A Olivo - Journal of Physics: Condensed Matter, 2021 - iopscience.iop.org
Although early demonstration dates back to the mid-sixties, x-ray phase-contrast imaging
(XPCI) became hugely popular in the mid-90s, thanks to the advent of 3rd generation …

Speckle-based x-ray phase-contrast and dark-field imaging with a laboratory source

I Zanette, T Zhou, A Burvall, U Lundström, DH Larsson… - Physical review …, 2014 - APS
We report on the observation and application of near-field speckles with a laboratory x-ray
source. The detection of speckles is possible thanks to the enhanced brilliance properties of …

Single-image geometric-flow x-ray speckle tracking

DM Paganin, H Labriet, E Brun, S Berujon - Physical Review A, 2018 - APS
We develop a speckle-tracking method for x-ray phase-contrast imaging, based on the
concept of geometric flow. This flow is a conserved current associated with deformation of …

Principles of different x-ray phase-contrast imaging: a review

S Tao, C He, X Hao, C Kuang, X Liu - Applied Sciences, 2021 - mdpi.com
Numerous advances have been made in X-ray technology in recent years. X-ray imaging
plays an important role in the nondestructive exploration of the internal structures of objects …

X-ray phase contrast imaging: From synchrotrons to conventional sources

A Olivo, E Castelli - La rivista del nuovo cimento, 2014 - Springer
Phase-based approaches can revolutionize X-ray imaging and remove its main limitation:
poor image contrast arising from low attenuation differences. They exploit the unit decrement …

Spatial resolution of edge illumination X-ray phase-contrast imaging

PC Diemoz, FA Vittoria, A Olivo - Optics express, 2014 - opg.optica.org
We analyze the spatial resolution of edge illumination X-ray phase-contrast imaging and its
dependence upon various experimental parameters such as source size, source-to-sample …

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

A Horng, J Stroebel, T Geith, S Milz… - Journal of Biomedical …, 2021 - Springer
Background The evolution of cartilage degeneration is still not fully understood, partly due to
its thinness, low radio-opacity and therefore lack of adequately resolving imaging …

[HTML][HTML] Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging

PC Diemoz, CK Hagen, M Endrizzi, A Olivo - Applied Physics Letters, 2013 - pubs.aip.org
We present a theoretical and experimental analysis of the angular sensitivity of edge
illumination X-ray phase-contrast imaging in its implementation with conventional X-ray …

Low‐dose phase contrast tomography with conventional x‐ray sources

CK Hagen, PRT Munro, M Endrizzi, PC Diemoz… - Medical …, 2014 - Wiley Online Library
Purpose: The edge illumination (EI) x‐ray phase contrast imaging (XPCi) method has been
recently further developed to perform tomographic and, thus, volumetric imaging. In this …