Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
X-ray phase-contrast imaging
M Endrizzi - Nuclear instruments and methods in physics research …, 2018 - Elsevier
X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of
samples. It finds application in a vast diversity of fields: medicine, biology, many engineering …
samples. It finds application in a vast diversity of fields: medicine, biology, many engineering …
Edge-illumination x-ray phase-contrast imaging
A Olivo - Journal of Physics: Condensed Matter, 2021 - iopscience.iop.org
Although early demonstration dates back to the mid-sixties, x-ray phase-contrast imaging
(XPCI) became hugely popular in the mid-90s, thanks to the advent of 3rd generation …
(XPCI) became hugely popular in the mid-90s, thanks to the advent of 3rd generation …
Speckle-based x-ray phase-contrast and dark-field imaging with a laboratory source
We report on the observation and application of near-field speckles with a laboratory x-ray
source. The detection of speckles is possible thanks to the enhanced brilliance properties of …
source. The detection of speckles is possible thanks to the enhanced brilliance properties of …
Single-image geometric-flow x-ray speckle tracking
We develop a speckle-tracking method for x-ray phase-contrast imaging, based on the
concept of geometric flow. This flow is a conserved current associated with deformation of …
concept of geometric flow. This flow is a conserved current associated with deformation of …
Principles of different x-ray phase-contrast imaging: a review
Numerous advances have been made in X-ray technology in recent years. X-ray imaging
plays an important role in the nondestructive exploration of the internal structures of objects …
plays an important role in the nondestructive exploration of the internal structures of objects …
X-ray phase contrast imaging: From synchrotrons to conventional sources
Phase-based approaches can revolutionize X-ray imaging and remove its main limitation:
poor image contrast arising from low attenuation differences. They exploit the unit decrement …
poor image contrast arising from low attenuation differences. They exploit the unit decrement …
Spatial resolution of edge illumination X-ray phase-contrast imaging
We analyze the spatial resolution of edge illumination X-ray phase-contrast imaging and its
dependence upon various experimental parameters such as source size, source-to-sample …
dependence upon various experimental parameters such as source size, source-to-sample …
Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation
A Horng, J Stroebel, T Geith, S Milz… - Journal of Biomedical …, 2021 - Springer
Background The evolution of cartilage degeneration is still not fully understood, partly due to
its thinness, low radio-opacity and therefore lack of adequately resolving imaging …
its thinness, low radio-opacity and therefore lack of adequately resolving imaging …
[HTML][HTML] Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging
We present a theoretical and experimental analysis of the angular sensitivity of edge
illumination X-ray phase-contrast imaging in its implementation with conventional X-ray …
illumination X-ray phase-contrast imaging in its implementation with conventional X-ray …
Low‐dose phase contrast tomography with conventional x‐ray sources
Purpose: The edge illumination (EI) x‐ray phase contrast imaging (XPCi) method has been
recently further developed to perform tomographic and, thus, volumetric imaging. In this …