IFGO optimized self-adaptive fuzzy-PID controlled HSAPF for PQ enhancement

AK Mishra, PK Nanda, PK Ray, SR Das… - International Journal of …, 2023 - Springer
In this article, a cost-effective Hybrid Shunt Active Power Filter (HSAPF) is presented for
compensation of harmonics and reactive power. Again, a novel estimation algorithm Robust …

[LLIBRE][B] Integration of renewable energy sources into the power grid through powerfactory

MZ Oskouei, B Mohammadi-Ivatloo - 2020 - books.google.com
This book evaluates a number of serious technical challenges related to the integration of
renewable energy sources into the power grid using the DIgSILENT PowerFactory power …

Integration of renewable energy sources

M Eidiani - Handbook of Smart Energy Systems, 2023 - Springer
Due to energy security issues and environmental concerns, renewable energy sources are
growing rapidly. Despite their many advantages, they can pose a challenge to power grids …

A comprehensive study on the renewable energy integration using DIgSILENT

M Eidiani, H Zeynal, Z Zakaria - 2023 IEEE 3rd International …, 2023 - ieeexplore.ieee.org
Renewable energy sources (RES) are growing rapidly as a result of energy security
requirements and the environmental concerns. In spite of their many advantages, they yet …

Evaluating the state of production reliability and adequacy indicators in the presence of renewable energy sources

M Eidiani, AA Puyan - Majlesi Journal of Mechatronic Systems, 2021 - ms.majlesi.info
With the growing relevance of reliability concerns in power grids and the rising penetration
of renewable energy sources in power systems, we've moved on to assessing a model grid …

[PDF][PDF] A four-line active shunt filter to enhance the power quality in a microgrid

A Mostefa, K Belalia, T Lantri… - International journal of …, 2023 - academia.edu
In recent years, power quality has become a major concern for electric network managers.
Active filtering control schemes ensure improved power quality of the electric network and …

[PDF][PDF] Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter

MY Lada, MAM Radzi, J Jasni, H Hizam… - Int J Pow Elec & Dri …, 2020 - academia.edu
Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application
due to capability to its produce low harmonic output current in which at the same time …

Electromagnetic Interference in Variable Frequency Drives used in Onshore Power Plants

D Hamza - 2024 IEEE Asia-Pacific Conference on Applied …, 2024 - ieeexplore.ieee.org
Electric power generation in onshore drilling platforms essentially depends on diesel
generators to supply the adequate voltage and current to drive high torque draw-work …

Network current quality enhancement under nonlinear and unbalanced load conditions using a four-wire inverter-based active shunt filter

K Belalia, M Khodja, H Bouzeboudja… - … Journal of Electrical …, 2021 - section.iaesonline.com
The flow of a large current in the neutral conductor of a transmission system is one of the
major problems caused by harmonic pollution. This current can assume excessive values …

Wind Energy Generation for Local Load with Improved Power Quality

P Yadav, TN Gupta - … on Emerging Frontiers in Electrical and …, 2022 - ieeexplore.ieee.org
The control technique for a wind energy generator with energy storage battery system
(ESBS) in an islanded Grid is presented in this research. This Islanded Micro Grid (IM G) …