Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study
Introduction To investigate the accuracy of preoperative digital templating for total hip
arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). Materials and …
arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). Materials and …
[HTML][HTML] Planning Accuracy and Stem Offset Assessment in Digital Two-Dimensional Versus Three-Dimensional Planning in Cementless Hip Arthroplasty: A …
FR Parisi, B Zampogna, A Zampoli, A Ferrini… - Journal of Clinical …, 2024 - mdpi.com
Background/Objectives: Total hip arthroplasty (THA) planning is crucial for restoring hip
function and minimizing complications. The present systematic review and meta-analysis …
function and minimizing complications. The present systematic review and meta-analysis …
Validation of mediCAD® software for fully digital preoperative planning of total hip arthroplasty: a retrospective study
PA Bouché, S Corsia, G Auberger, J Descamps… - … & Traumatology: Surgery …, 2024 - Elsevier
Introduction The planning step that precedes a total hip arthroplasty (THA) procedure is
crucial. Digital planning software programs are being increasingly used, although few …
crucial. Digital planning software programs are being increasingly used, although few …
Accuracy of two-dimensional digital planning in uncemented primary hip arthroplasty: monocentric analysis of eight hundred implants
B Zampogna, FR Parisi, A Zampoli, A Prezioso… - International …, 2024 - Springer
Purpose In the last decades, there has been a refinement in total hip arthroplasty, which
allowed surgeons to achieve the highest performance and better patient outcomes …
allowed surgeons to achieve the highest performance and better patient outcomes …
Pre‐operative templating for total hip arthroplasty: How does radiographic technique and calibration marker placement affect image magnification?
M Holliday, A Steward - Journal of Medical Radiation Sciences, 2021 - Wiley Online Library
Introduction Pre‐operative templating using digital radiography is an effective method of
planning for total hip arthroplasty (THA) and requires a generalised fixed magnification …
planning for total hip arthroplasty (THA) and requires a generalised fixed magnification …
The accuracy of external calibration markers in digital templating using the double marker and single marker method: a comparative study
Y Warschawski, I Shichman, S Morgan… - Archives of Orthopaedic …, 2020 - Springer
Background Digital templating is an essential step in the preoperative planning of total hip
arthroplasty (THA). Previous studies have suggested that templating with the double marker …
arthroplasty (THA). Previous studies have suggested that templating with the double marker …
Magnification of digital hip radiographs differs between clinical workplaces
J Hornová, P Růžička, M Hrubina, E Šťastný… - PLoS …, 2017 - journals.plos.org
Preoperative planning for total hip arthroplasty includes templating on anteroposterior
radiographs. It is necessary to consider radiographic magnification in order to scale …
radiographs. It is necessary to consider radiographic magnification in order to scale …
Reliably calibrating X-ray images required for preoperative planning of THA using a device-adapted magnification factor
H Brüggemann, A Paulsen, K Oppedal, M Grasmair… - Plos one, 2024 - journals.plos.org
Background and aim Calibrated pelvic X-ray images are needed in the preoperative
planning of total hip arthroplasty (THA) to predict component sizes. Errors and mismatch in …
planning of total hip arthroplasty (THA) to predict component sizes. Errors and mismatch in …
Does two dimensional templating allow for the use of reduced-size ancillaries in total hip arthroplasty?
G Heliere, G David, S Cypel, V Steiger… - International …, 2024 - Springer
Purpose Rising costs in healthcare for total hip arthroplasty (THA) mean that new solutions
must be considered, such as the use of single-use ancillaries (SUA). The goal of this study …
must be considered, such as the use of single-use ancillaries (SUA). The goal of this study …
Evaluation of a stepped, fixed-height magnification marker stand for use with a 100-mm marker in implant sizing prediction in 52 total hip replacement procedures in …
HK Siemon, WD Liska, SK Israel - Plos one, 2023 - journals.plos.org
Objective To describe the use of a 100-millimeter marker placed on a stepped, fixed-height
magnification marker stand to measure radiographic magnification on accuracy of implant …
magnification marker stand to measure radiographic magnification on accuracy of implant …