Calibrated measurement of optoelectronic frequency response
Calibrated measurement of optoelectronic frequency response Page 1 1422 IEEE
TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 51, NO. 4, APRIL 2003 …
TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, VOL. 51, NO. 4, APRIL 2003 …
Calibration of sampling oscilloscopes with high-speed photodiodes
We calibrate the magnitude and phase response of equivalent-time sampling oscilloscopes
to 110 GHz. We use a photodiode that has been calibrated with our electrooptic sampling …
to 110 GHz. We use a photodiode that has been calibrated with our electrooptic sampling …
50 years of RF and microwave sampling
M Kahrs - IEEE Transactions on Microwave Theory and …, 2003 - ieeexplore.ieee.org
Measurement of microwave and UHF signals is often done with sampling techniques. In this
paper, the techniques and technology of sampling of electrical signals is reviewed from …
paper, the techniques and technology of sampling of electrical signals is reviewed from …
Waveform metrology: signal measurements in a modulated world
We review the waveform metrology program developed over many years at the National
Institute of Standards and Technology. The goal of this program is to provide a measurement …
Institute of Standards and Technology. The goal of this program is to provide a measurement …
The sampling oscilloscope as a microwave instrument
Most of the equipment required is readily available in most microwave labs: a vector network
analyzer, a microwave signal generator, and, of course, a sampling oscilloscope. In this …
analyzer, a microwave signal generator, and, of course, a sampling oscilloscope. In this …
A review of measurement methods for traceable calibration of waveform recorders used in ElectroShock Weapons (ESWs) testing
Nowadays, finding a proper method to calibrate the measurement systems (eg waveform
recorders) used for accurate characterization of the signals generated by electroshock …
recorders) used for accurate characterization of the signals generated by electroshock …
Calibrating electro-optic sampling systems
We apply frequency-domain impedance mismatch corrections to a temporal electro-optic
sampling system and use it to characterize the magnitude and phase response of a …
sampling system and use it to characterize the magnitude and phase response of a …
Comb-generator characterization
We characterize a 50-GHz comb generator with a sampling oscilloscope. With careful
control of the input power, input harmonics, and comb generator temperature, we measure …
control of the input power, input harmonics, and comb generator temperature, we measure …
Minimum-phase calibration of sampling oscilloscopes
We describe an algorithm for determining the minimum phase of a linear time-invariant
response function from its magnitude. The procedure is based on Kramers-Kronig relations …
response function from its magnitude. The procedure is based on Kramers-Kronig relations …
Adaptive characterization of jitter noise in sampled high-speed signals
We estimate the root-mean-square (RMS) value of timing jitter noise in simulated signals
similar to measured high-speed sampled signals. The simulated signals are contaminated …
similar to measured high-speed sampled signals. The simulated signals are contaminated …