Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Modeling and analysis approaches for small‐signal stability assessment of power‐electronic‐dominated systems
The stability, operation, and control of power networks have been challenged due to the
increased penetration of power electronic converters. New instability phenomena have …
increased penetration of power electronic converters. New instability phenomena have …
Small signal dynamics of DFIG-based wind turbines during riding through symmetrical faults in weak AC grid
J Hu, B Wang, W Wang, H Tang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Instability issues of the grid-connected doubly fed induction generator (DFIG) based wind
turbines (WTs) during low-voltage ride-through (LVRT) have got little attention yet. In this …
turbines (WTs) during low-voltage ride-through (LVRT) have got little attention yet. In this …
Analysis of subsynchronous torsional interaction with power electronic converters
L Harnefors - IEEE Transactions on power systems, 2007 - ieeexplore.ieee.org
This paper extends previously proposed methods for frequency-domain analysis of
subsynchronous oscillation phenomena in synchronous machines. Particular attention is …
subsynchronous oscillation phenomena in synchronous machines. Particular attention is …
A case study on the application of the Nyquist stability criterion as applied to interconnected loads and sources on grids
R Turner, S Walton, R Duke - IEEE Transactions on Industrial …, 2012 - ieeexplore.ieee.org
As the penetration of complex grid-connected devices, such as power electronic inverters,
increases, so too does the complexity of analyzing system stability. A graphical application …
increases, so too does the complexity of analyzing system stability. A graphical application …
Stability analysis on torsional interactions of turbine-generator connected with DFIG-WECS using admittance model
To evaluate the stability of Subsynchronous Torsional Interactions (SSTI), we propose a
simple and effective approach using admittance model. The proposed approach gives the …
simple and effective approach using admittance model. The proposed approach gives the …
Proof and application of the positive-net-dam** stability criterion
L Harnefors - IEEE Transactions on Power Systems, 2010 - ieeexplore.ieee.org
Proof and Application of the Positive-Net-Dam** Stability Criterion Page 1 IEEE
TRANSACTIONS ON POWER SYSTEMS, VOL. 26, NO. 1, FEBRUARY 2011 481 Proof and …
TRANSACTIONS ON POWER SYSTEMS, VOL. 26, NO. 1, FEBRUARY 2011 481 Proof and …
Small-signal dynamic model and analysis of a fixed-speed wind farm-a frequency response approach
A Tabesh, R Iravani - IEEE Transactions on power delivery, 2006 - ieeexplore.ieee.org
This paper introduces a small-signal dynamic model of a fixed-frequency (induction machine
based) wind farm connected to an electrical power system. The model represents the system …
based) wind farm connected to an electrical power system. The model represents the system …
[HTML][HTML] Frequency domain solution method for electromagnetic influence analysis on torsional vibrations
In electric motor-driven machines, mechanical torsional dynamics are nonlinearly coupled
with the electrical system through the electromagnetic torque and the counter-electromotive …
with the electrical system through the electromagnetic torque and the counter-electromotive …
Robust nonlinear control via feedback linearization and Lyapunov theory for permanent magnet synchronous generator-based wind energy conversion system
In this paper, the method for the nonlinear control design of a permanent magnet
synchronous generator based-wind energy conversion system (WECS) is proposed in order …
synchronous generator based-wind energy conversion system (WECS) is proposed in order …
Net dam** criterion for stability analysis of grid-tied VSCs in DC voltage control timescale
Stability of grid-connected VSCs in DC voltage control (DVC) timescales (ie, the frequency
range of dynamics covering converter outer controls) has recently caught increased …
range of dynamics covering converter outer controls) has recently caught increased …