Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications
In this paper, the authors' review the applicability of the open‐source GATE Monte Carlo
simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry …
simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry …
Dosimetry of internal emitters
G Sgouros - Journal of Nuclear Medicine, 2005 - jnm.snmjournals.org
Response and toxicity prediction is essential to rational implementation of cancer therapy.
The biologic effects of radionuclide therapy are mediated via a well-defined physical …
The biologic effects of radionuclide therapy are mediated via a well-defined physical …
All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry
R Kramer, JW Vieira, HJ Khoury… - Physics in Medicine & …, 2003 - iopscience.iop.org
Abstract The MAX (Male Adult voXel) phantom has been developed from existing
segmented images of a male adult body, in order to achieve a representation as close as …
segmented images of a male adult body, in order to achieve a representation as close as …
Método de Monte Carlo: princípios e aplicações em Física Médica
H Yoriyaz - Revista Brasileira de Física Médica, 2009 - rbfm.org.br
O método de Monte Carlo tem se tornado, ao longo dos anos, uma ferramenta padrão para
cálculos de dose absorvida e outras grandezas de interesse nas áreas de terapêutica e …
cálculos de dose absorvida e outras grandezas de interesse nas áreas de terapêutica e …
Monte Carlo MCNP-4B–based absorbed dose distribution estimates for patient-specific dosimetry
H Yoriyaz, MG Stabin… - Journal of Nuclear …, 2001 - jnm.snmjournals.org
This study was intended to verify the capability of the Monte Carlo MCNP-4B code to
evaluate spatial dose distribution based on information gathered from CT or SPECT …
evaluate spatial dose distribution based on information gathered from CT or SPECT …
Development and validation of RAPID: a patient-specific Monte Carlo three-dimensional internal dosimetry platform
This work describes the development and validation of a patient-specific Monte Carlo
internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for …
internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for …
Three-dimensional imaging-based radiobiological dosimetry
Targeted radionuclide therapy holds promise as a new treatment for cancer. Advances in
imaging are making it possible for researchers to evaluate the spatial distribution of …
imaging are making it possible for researchers to evaluate the spatial distribution of …
The application of voxel phantoms to the internal dosimetry of radionuclides
M Zankl, N Petoussi-Henss, U Fill… - Radiation protection …, 2003 - academic.oup.com
Extensive calculations of specific absorbed fractions (SAFs) for monoenergetic photon
sources were performed using a Monte Carlo photon transport code together with seven …
sources were performed using a Monte Carlo photon transport code together with seven …
Voxel-based models representing the male and female ICRP reference adult—the skeleton
M Zankl, KF Eckerman, WE Bolch - Radiation protection …, 2007 - academic.oup.com
For the forthcoming update of organ dose conversion coefficients, the International
Commission on Radiological Protection (ICRP) will use voxel-based computational …
Commission on Radiological Protection (ICRP) will use voxel-based computational …
Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases
The lungs are the most frequent sites of distant metastasis in differentiated thyroid
carcinoma. Radioiodine treatment planning for these patients is usually performed following …
carcinoma. Radioiodine treatment planning for these patients is usually performed following …