X-ray computed tomography

PJ Withers, C Bouman, S Carmignato… - Nature Reviews …, 2021 - nature.com
X-ray computed tomography (CT) can reveal the internal details of objects in three
dimensions non-destructively. In this Primer, we outline the basic principles of CT and …

Parameter identification of a phase-field fracture model using integrated digital image correlation

V Kosin, A Fau, C Jailin, F Hild, T Wick - Computer Methods in Applied …, 2024 - Elsevier
Phase-field fracture (PFF) modeling is a popular approach to model and simulate fracture
processes in solids. Accurate material parameters and boundary conditions are of utmost …

[HTML][HTML] Dual beam microfocus high-energy tomography: Towards multimodal and faster laboratory experiments

E Maire, G Bonnard, J Adrien, X Boulnat… - Tomography of Materials …, 2024 - Elsevier
This paper discusses the development of a Dual Beam microfocus high-energy X-ray
tomography system for laboratory experiments, aiming to enhance temporal resolution and …

A projection-based approach to extend digital volume correlation for 4D spacetime measurements

V Kosin, A Fau, C Jailin… - Comptes …, 2023 - comptes-rendus.academie-sciences …
In-situ (tomography) experiments are generally based on scans reconstructed from a large
number of projections acquired under constant deformation of samples. Standard digital …

Toward high fidelity materials property prediction from multiscale modeling and simulation

M Vassaux, RC Sinclair, RA Richardson… - Advanced Theory …, 2020 - Wiley Online Library
The current approach to materials discovery and design remains dominated by experimental
testing, frequently based on little more than trial and error. With the advent of ever more …

Sub-minute in situ fracture test in a laboratory CT scanner

C Jailin, A Bouterf, R Vargas, F Hild, S Roux - Integrating Materials and …, 2019 - Springer
The present study aims at demonstrating the feasibility of performing a fracture test in less
than 1 min in a laboratory CT scanner despite the severe time constraints of tomography …

[HTML][HTML] pt4: Phantom-4D, an open-source software tool for creating time-evolving 3D phantoms

S Catsamas, G Myers, A Kingston - Tomography of Materials and …, 2024 - Elsevier
Abstract pt 4, an open-source software tool to describe time-evolving phantoms is presented.
pt 4 allows users to create detailed time-evolving phantoms for testing novel 4D-CT …

Digital volume correlation of laminographic and tomographic images: Results and challenges

A Bouterf, A Buljac, F Hild, C Jailin, J Neggers… - Virtual Design and …, 2020 - Springer
Although digital volume correlation (DVC) seems to be a simple extension of digital image
correlation to 3D situations, new challenges arise. The first problem is that the actual …

Modal decomposition from partial measurements

C Jailin, S Roux - Comptes Rendus. Mécanique, 2019 - comptes-rendus.academie-sciences …
In experimental mechanics, full-field measurements are an essential ingredient for the
identification and validation of mechanical laws. Initially developed for 2D plane …

[CITAT][C] General Time-resolved Computed Tomography from First Principles

S Catsamas - 2023 - The Australian National University