[HTML][HTML] Pros and cons of ultra-high-field MRI/MRS for human application

ME Ladd, P Bachert, M Meyerspeer, E Moser… - Progress in nuclear …, 2018 - Elsevier
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both
for clinical diagnostic applications and in basic research areas such as cognitive …

In vivo B0 field shimming methods for MRI at 7 T

JP Stockmann, LL Wald - Neuroimage, 2018 - Elsevier
Abstract Functional MRI (fMRI) at 7 T and above provides improved Signal-to-Noise Ratio
and Contrast-to-Noise Ratio compared to 3 T acquisitions. In addition to the beneficial …

B0 shimming for in vivo magnetic resonance spectroscopy: Experts' consensus recommendations

C Juchem, C Cudalbu, RA de Graaf… - NMR in …, 2021 - Wiley Online Library
Magnetic resonance spectroscopy (MRS) and spectroscopic imaging (MRSI) allow the
chemical analysis of physiological processes in vivo and provide powerful tools in the life …

Reduced striatal GABA in unmedicated children with ADHD at 7T

NA Puts, M Ryan, G Oeltzschner, A Horska… - Psychiatry Research …, 2020 - Elsevier
Attention-deficit hyperactive disorder (ADHD) is characterized by inattention and increased
impulsive and hypermotoric behaviors. Despite the high prevalence and impact of ADHD …

Advancements in gradient system performance for clinical and research MRI

N Gudino, S Littin - Journal of Magnetic Resonance Imaging, 2023 - Wiley Online Library
In magnetic resonance imaging (MRI), spatial field gradients are applied along each axis to
encode the location of the nuclear spin in the frequency domain. During recent years, the …

Retrospective correction of physiological field fluctuations in high‐field brain MRI using concurrent field monitoring

SJ Vannesjo, BJ Wilm, Y Duerst, S Gross… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose Magnetic field fluctuations caused by subject motion, such as breathing or limb
motion, can degrade image quality in brain MRI, especially at high field strengths. The …

[HTML][HTML] Map** of brain macromolecules and their use for spectral processing of 1H-MRSI data with an ultra-short acquisition delay at 7 T

M Považan, G Hangel, B Strasser, S Gruber, M Chmelik… - Neuroimage, 2015 - Elsevier
Long echo time (TE) MR spectroscopy (MRS) sequences are sensitive only to metabolites of
low molecular weight. At shorter TE, significantly more metabolite signals are detectable …

Real-time motion-and B0-correction for LASER-localized spiral-accelerated 3D-MRSI of the brain at 3 T

W Bogner, AT Hess, B Gagoski, MD Tisdall… - Neuroimage, 2014 - Elsevier
The full potential of magnetic resonance spectroscopic imaging (MRSI) is often limited by
localization artifacts, motion-related artifacts, scanner instabilities, and long measurement …

Real‐time feedback for spatiotemporal field stabilization in MR systems

Y Duerst, BJ Wilm, BE Dietrich… - Magnetic resonance …, 2015 - Wiley Online Library
Purpose MR imaging and spectroscopy require a highly stable, uniform background field.
The field stability is typically limited by hardware imperfections, external perturbations, or …

[HTML][HTML] Quantitative T1 map** using multi-slice multi-shot inversion recovery EPI

RMS Panchuelo, O Mougin, R Turner, ST Francis - NeuroImage, 2021 - Elsevier
An efficient multi-slice inversion–recovery EPI (MS-IR-EPI) sequence for fast, high spatial
resolution, quantitative T 1 map** is presented, using a segmented simultaneous multi …