Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
MRI‐based myelin water imaging: a technical review
Multiexponential T2 relaxation time measurement in the central nervous system shows a
component that originates from water trapped between the lipid bilayers of myelin. This …
component that originates from water trapped between the lipid bilayers of myelin. This …
Magnetic resonance fingerprinting
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The
basic structure of a magnetic resonance experiment has remained largely unchanged for …
basic structure of a magnetic resonance experiment has remained largely unchanged for …
MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout
Purpose This study explores the possibility of using gradient echo‐based sequences other
than balanced steady‐state free precession (bSSFP) in the magnetic resonance …
than balanced steady‐state free precession (bSSFP) in the magnetic resonance …
Dynamic contrast-enhanced (DCE) MRI
Background Dynamic contrast-enhanced (DCE) MRI is an integral part of several standard
of care MRI protocols for disease diagnosis, such as in the breast 1 and the prostate. 2 DCE …
of care MRI protocols for disease diagnosis, such as in the breast 1 and the prostate. 2 DCE …
Global and local fMRI signals driven by neurons defined optogenetically by type and wiring
Despite a rapidly-growing scientific and clinical brain imaging literature based on functional
magnetic resonance imaging (fMRI) using blood oxygenation level-dependent (BOLD) …
magnetic resonance imaging (fMRI) using blood oxygenation level-dependent (BOLD) …
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Purpose The purpose of this study was to accelerate the acquisition and reconstruction time
of 3D magnetic resonance fingerprinting scans. Methods A 3D magnetic resonance …
of 3D magnetic resonance fingerprinting scans. Methods A 3D magnetic resonance …
Slice profile and B1 corrections in 2D magnetic resonance fingerprinting
Purpose The goal of this study is to characterize and improve the accuracy of 2D magnetic
resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 …
resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 …
B-spline parameterized joint optimization of reconstruction and k-space trajectories (bjork) for accelerated 2d mri
Optimizing k-space sampling trajectories is a promising yet challenging topic for fast
magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method …
magnetic resonance imaging (MRI). This work proposes to optimize a reconstruction method …
Automated design of pulse sequences for magnetic resonance fingerprinting using physics-inspired optimization
Magnetic resonance fingerprinting (MRF) is a method to extract quantitative tissue properties
such as T 1 and T 2 relaxation rates from arbitrary pulse sequences using conventional MRI …
such as T 1 and T 2 relaxation rates from arbitrary pulse sequences using conventional MRI …
SPARKLING: variable‐density k‐space filling curves for accelerated T2*‐weighted MRI
Purpose To present a new optimition‐driven design of optimal k‐space trajectories in the
context of compressed sensing: Spreading Projection Algorithm for Rapid K‐space …
context of compressed sensing: Spreading Projection Algorithm for Rapid K‐space …