A review of surgical bone drilling and drill bit heat generation for implantation
This study aims to summarize the current state of scientific knowledge on factors that
contribute to heat generation during the bone drilling process and how these aspects can be …
contribute to heat generation during the bone drilling process and how these aspects can be …
Thermal and physical damage in skull base drilling using gas cooling modes: FEM simulation and experimental evaluation
S Gholampour, HH Hassanalideh… - Computer Methods and …, 2021 - Elsevier
Background Skull base drilling, as a high-risk process, is one of the most important
techniques of skull base surgeries. Methods The temperature, thrust force, and torque were …
techniques of skull base surgeries. Methods The temperature, thrust force, and torque were …
Ultrasonic-assisted drilling of cortical and cancellous bone in a comparative point of view
Background During bone drilling, a common procedure in clinical surgeries, excessive heat
generation and drilling force can cause damage to bone tissue, potentially leading to failure …
generation and drilling force can cause damage to bone tissue, potentially leading to failure …
Pin Site Care
The protection of the bone–pin interface is vital for the successful completion of any fixator-
assisted reconstructive procedure. Losing this interface through infection and/or loosening …
assisted reconstructive procedure. Losing this interface through infection and/or loosening …
Investigation of Drilling Parameters Affecting Borehole Circularity in Cortical Bone
Cortical bone drilling is a critical step performed prior to implant bolt placement, where
drilling parameters play a significant role in the success of the procedure. This study …
drilling parameters play a significant role in the success of the procedure. This study …
[PDF][PDF] Determination of convective heat transfer coefficient in human femur bone drilling in the presence of normal saline and evaluation of effective parameters
S Sadri, J Ghasemi - Amirkabir Journal of Mechanical Engineering, 2023 - mej.aut.ac.ir
This research has analyzed the drilling process in the human femur bone to determine the
heat transfer coefficient and occurrence or non-occurrence of thermal necrosis. 3D drilling …
heat transfer coefficient and occurrence or non-occurrence of thermal necrosis. 3D drilling …
KAJIAN PARAMETER PENGEBORAN TERHADAP PENYIMPANGAN DIAMETER TULANG KORTIKAL DENGAN METODE RSM
GD ARZAQ - 2024 - digilib.unila.ac.id
Pengeboran pada tulang kortikal adalah operasi yang pasti dilakukan jika terjadi
kecelakaan pada patah tulang dan merupakan prosedur bedah utama sebelum …
kecelakaan pada patah tulang dan merupakan prosedur bedah utama sebelum …
تعیین ضریب انتقال حرارت همرفتی در سوراخکاری استخوان فمور انسان در حضور نرمالسالین و بررسی پارامترهای موثر درآن
صدری, شیرزاد, قاسمی, جلال - نشریه مهندسی مکانیک امیرکبیر, 2023 - mej.aut.ac.ir
این تحقیق به تحلیل سوراخکاری در استخوان فمور انسان برای تعیین ضریب انتقال حرارت
جابجایی و بررسی بروز نکروز حرارتی پرداخته است. شبیهسازی سهبعدی سوراخکاری در حالت …
جابجایی و بررسی بروز نکروز حرارتی پرداخته است. شبیهسازی سهبعدی سوراخکاری در حالت …