Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Time domain functional NIRS imaging for human brain map**
This review is aimed at presenting the state-of-the-art of time domain (TD) functional near-
infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of …
infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of …
New frontiers in time-domain diffuse optics, a review
The recent developments in time-domain diffuse optics that rely on physical concepts (eg,
time-gating and null distance) and advanced photonic components (eg, vertical cavity …
time-gating and null distance) and advanced photonic components (eg, vertical cavity …
A brief review on the use of functional near-infrared spectroscopy (fNIRS) for language imaging studies in human newborns and adults
Upon stimulation, real time maps of cortical hemodynamic responses can be obtained by
non-invasive functional near-infrared spectroscopy (fNIRS) which measures changes in …
non-invasive functional near-infrared spectroscopy (fNIRS) which measures changes in …
BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the …
The BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and
built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring …
built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring …
Comparison of a layered slab and an atlas head model for Monte Carlo fitting of time-domain near-infrared spectroscopy data of the adult head
J Selb, TM Ogden, J Dubb, Q Fang… - Journal of biomedical …, 2014 - spiedigitallibrary.org
Near-infrared spectroscopy (NIRS) estimations of the adult brain baseline optical properties
based on a homogeneous model of the head are known to introduce significant …
based on a homogeneous model of the head are known to introduce significant …
Sustained fatigue assessment during isometric exercises with time-domain near infrared spectroscopy and surface electromyography signals
The effect of sustained fatigue during an upper limb isometric exercise is presented to
investigate a group of healthy subjects with simultaneous time-domain (TD) NIRS and …
investigate a group of healthy subjects with simultaneous time-domain (TD) NIRS and …
Probe-hosted silicon photomultipliers for time-domain functional near-infrared spectroscopy: phantom and in vivo tests
We report the development of a compact probe for time-domain (TD) functional near-infrared
spectroscopy (fNIRS) based on a fast silicon photomultiplier (SiPM) that can be put directly …
spectroscopy (fNIRS) based on a fast silicon photomultiplier (SiPM) that can be put directly …
Multi-channel medical device for time domain functional near infrared spectroscopy based on wavelength space multiplexing
We have designed a compact dual wavelength (687 nm, 826 nm) multi-channel (16 sources,
8 detectors) medical device for muscle and brain imaging based on time domain functional …
8 detectors) medical device for muscle and brain imaging based on time domain functional …
Reliable fast (20 Hz) acquisition rate by a TD fNIRS device: brain resting-state oscillation studies
A high power setup for multichannel time-domain (TD) functional near infrared spectroscopy
(fNIRS) measurements with high efficiency detection system was developed. It was fully …
(fNIRS) measurements with high efficiency detection system was developed. It was fully …
Effect of adipose tissue thickness and tissue optical properties on the differential pathlength factor estimation for NIRS studies on human skeletal muscle
We propose a quantitative and systematic investigation of the differential pathlength factor
(DPF) behavior for skeletal muscles and its dependence on different factors, such as the …
(DPF) behavior for skeletal muscles and its dependence on different factors, such as the …