Excellent-moisture-resistance fluorinated polyimide composite film and self-powered acoustic sensing
CH Li, Z Huang, J Lin, T Hou, Y Zi… - ACS Applied Materials & …, 2023 - ACS Publications
As a clean, sustainable energy source, sound can carry a wealth of information and play a
huge role in the Internet of Things era. In recent years, triboelectric acoustic sensors have …
huge role in the Internet of Things era. In recent years, triboelectric acoustic sensors have …
[HTML][HTML] Review of various sensor technologies in monitoring the condition of power transformers
Modern power grids are undergoing a significant transformation with the massive integration
of renewable, decentralized, and electronically interfaced energy sources, alongside new …
of renewable, decentralized, and electronically interfaced energy sources, alongside new …
Partial Discharge Detection Using Piezoelectric Sensors on Power Transformer: A Review
SN Meitei - IEEE Sensors Journal, 2024 - ieeexplore.ieee.org
Partial discharge (PD) in the power transformer is one of the signs of an issue with the
insulation system. The prolonged presence of this phenomenon has the potential to lead to …
insulation system. The prolonged presence of this phenomenon has the potential to lead to …
Low-cost online partial discharge monitoring system for power transformers
W Sikorski, A Wielewski - Sensors, 2023 - mdpi.com
The article presents in detail the construction of a low-cost, portable online PD monitoring
system based on the acoustic emission (AE) technique. A highly sensitive piezoelectric …
system based on the acoustic emission (AE) technique. A highly sensitive piezoelectric …
Denoising of partial discharge signal using a hybrid framework of total variation denoising-autoencoder
Partial discharge (PD) measurement is an essential task for assessing the condition of
electrical insulations. Different types of noises, such as random noise and discrete spectral …
electrical insulations. Different types of noises, such as random noise and discrete spectral …
Efficient partial discharge signal denoising method via adaptive variational modal decomposition for infrared detectors
Y Deng, K Zhu, G Zhao, J Zhu - Infrared Physics & Technology, 2022 - Elsevier
Partial discharge detection is one of the effective means for judging cable insulation
condition. However, subject to the operating environment of the cable, the measured signal …
condition. However, subject to the operating environment of the cable, the measured signal …
Investigation of partial discharges within power oil transformers by acoustic emission
F Witos, A Olszewska - Energies, 2023 - mdpi.com
This paper presents the authors' multi-channel measurement systems designed and built to
conduct research on partial discharge phenomena using the acoustic emission method. The …
conduct research on partial discharge phenomena using the acoustic emission method. The …
Acoustic based localization of partial discharge inside oil-filled transformers
This paper addresses the localization of Partial Discharge through a 3D Finite Element
Method analysis of acoustic wave propagation inside a 3-phase 35kV transformer with the …
Method analysis of acoustic wave propagation inside a 3-phase 35kV transformer with the …
Application of machine learning to express measurement uncertainty
The continuing increase in data processing power in modern devices and the availability of
a vast amount of data via the internet and the internet of things (sensors, monitoring systems …
a vast amount of data via the internet and the internet of things (sensors, monitoring systems …
Evaluation of a calibration technique in measuring partial discharges inside mineral oils with a high‐frequency current transformer (HFCT) sensor: A case study
Partial discharge is one of the main reasons for insulation degradation in high‐voltage
apparatuses. Partial discharge is an ineluctable phenomenon that happens when a high …