Real‐time scatter estimation for medical CT using the deep scatter estimation: method and robustness analysis with respect to different anatomies, dose levels, tube …
Purpose X‐ray scattering leads to CT images with a reduced contrast, inaccurate CT values
as well as streak and cup** artifacts. Therefore, scatter correction is crucial to maintain the …
as well as streak and cup** artifacts. Therefore, scatter correction is crucial to maintain the …
X-ray scatter estimation using deep splines
X-ray scatter compensation is a very desirable technique in flat-panel X-ray imaging and
cone-beam computed tomography. State-of-the-art U-net based scatter removal approaches …
cone-beam computed tomography. State-of-the-art U-net based scatter removal approaches …
Empirical scatter correction: CBCT scatter artifact reduction without prior information
Background The image quality of cone beam CT (CBCT) scans severely suffers from
scattered radiation if no countermeasures are taken. Scatter artifacts may induce cup** …
scattered radiation if no countermeasures are taken. Scatter artifacts may induce cup** …
Appearance learning for image-based motion estimation in tomography
In tomographic imaging, anatomical structures are reconstructed by applying a pseudo-
inverse forward model to acquired signals. Geometric information within this process is …
inverse forward model to acquired signals. Geometric information within this process is …
Symmetry prior for epipolar consistency
Purpose For a perfectly plane symmetric object, we can find two views—mirrored at the
plane of symmetry—that will yield the exact same image of that object. In consequence …
plane of symmetry—that will yield the exact same image of that object. In consequence …
Maximum likelihood estimation of head motion using epipolar consistency
Open gantry C-arm systems that are placed within the interventional room enable 3-D
imaging and guidance for stroke therapy without patient transfer. This can profit in drastically …
imaging and guidance for stroke therapy without patient transfer. This can profit in drastically …
[PDF][PDF] Multipositional x-ray tomography for avoidance and reduction of image artefacts
G Herl - 2022 - opus4.kobv.de
X-ray computed tomography (CT) is a widely used imaging technique in both medicine and
industry. In recent years, robot-supported CT systems have been researched and …
industry. In recent years, robot-supported CT systems have been researched and …
Breathing motion detection in computed tomography using data consistency conditions
M Mouchet - 2022 - theses.hal.science
Four-dimensional (4D) computed tomography (CT) images are used for the radiotherapy
planning of thoracic and upper-abdominal tumors to account for breathing motion. It …
planning of thoracic and upper-abdominal tumors to account for breathing motion. It …
Motion Compensation via Epipolar Consistency for In-Vivo X-Ray Microscopy
Intravital X-ray microscopy (XRM) in preclinical mouse models is of vital importance for the
identification of microscopic structural pathological changes in the bone which are …
identification of microscopic structural pathological changes in the bone which are …
Artifact correction and real-time scatter estimation for X-ray computed tomography in industrial metrology
J Maier - 2019 - archiv.ub.uni-heidelberg.de
Artifacts often limit the application of computed tomography (CT) in industrial metrology. In
order to correct these artifacts, the so-called simulation-based artifact correction (SBAC) was …
order to correct these artifacts, the so-called simulation-based artifact correction (SBAC) was …