AC, DC, and hybrid control strategies for smart microgrid application: A review

B Sahoo, SK Routray, PK Rout - International Transactions on …, 2021 - Wiley Online Library
Smart microgrid concept‐based AC, DC, and hybrid‐MG architecture is gaining popularity
due to the excess use of distributed renewable energy generation (DRE). Looking at the …

Power quality and stability improvement of microgrid through shunt active filter control application: An overview

B Sahoo, MM Alhaider, PK Rout - Renewable Energy Focus, 2023 - Elsevier
Owing to avoid harmonic and power quality issues, the concept of eliminating their impacts
on microgrid systems has gained a lot of interest. Incidentally, shunt active filters (SHAFs) is …

A hybrid control topology for cascaded H-bridge multilevel inverter to improve the power quality of smart grid connected system: NBO-RERNN approach

CR Rajesh, P Meenalochini, SK Kannaiah… - Expert Systems with …, 2024 - Elsevier
This manuscript proposes a hybrid control technique for the grid-connected photovoltaic
(PV) generation system with a cascaded multilevel inverter (CMLI). The proposed hybrid …

Neural networks based shunt hybrid active power filter for harmonic elimination

M Iqbal, M Jawad, MH Jaffery, S Akhtar, MN Rafiq… - IEEE …, 2021 - ieeexplore.ieee.org
The growing use of nonlinear devices is introducing harmonics in power system networks
that result in distortion of current and voltage signals causing damage to power distribution …

Design and implementation of 31-level asymmetrical inverter with reduced components

D Prasad, C Dhanamjayulu, S Padmanaban… - IEEE …, 2021 - ieeexplore.ieee.org
This paper presents a novel topology for the single-phase 31-level asymmetrical multilevel
inverter accomplished with reduced components count. The proposed topology generates …

[HTML][HTML] Wind energy integration: Dynamic modeling and control of DFIG based on super twisting fractional order terminal sliding mode controller

MA Soomro, ZA Memon, M Kumar, MH Baloch - Energy Reports, 2021 - Elsevier
The stator voltage and frequency variations of doubly fed induction generator (DFIG) make it
impossible to maintain direct connection to the power grid Moreover, uncertainty, inequity …

A novel centralized energy management approach for power quality improvement

B Sahoo, SK Routray, PK Rout - International Transactions on …, 2021 - Wiley Online Library
This manuscript proposes a novel centralized energy management approach (CEMA) for
power quality (PQ) improvement in a solar‐battery based hybrid microgrid systems (HMSs) …

Integration of wind power generation through an enhanced instantaneous power theory

B Sahoo, SK Routray, PK Rout - IET Energy Systems Integration, 2020 - Wiley Online Library
This study deals with the operation of the wind power generation system (WPGS) having
active filter capabilities using the grid‐interfacing converter (GIC) control approach. A novel …

Effective harmonic cancellation technique for a three-phase four-wire system

B Sahoo, MM Alhaider, PK Rout - Energies, 2022 - mdpi.com
An excess non-linear and unbalanced load application increases the power quality (PQ)
problem by injecting harmonic current. The avoidance of neutral current control creates …

A novel sensorless current sha** control approach for SVPWM inverter with voltage disturbance rejection in a dc grid–based wind power generation system

B Sahoo, SK Routray, PK Rout - Wind Energy, 2020 - Wiley Online Library
A novel sensorless current sha** (CS) control strategy is proposed to avail better power
quality (PQ) of a dc grid–based wind power generation system (WPGS) used on a poultry …