[HTML][HTML] Waste heat recoveries in data centers: A review
Data centers (DCs) uninterruptedly run 24/24 h, 365 days per year with much huge
operating scale, and have the characteristics of high operation safety requirement, high heat …
operating scale, and have the characteristics of high operation safety requirement, high heat …
Data centers cooling: a critical review of techniques, challenges, and energy saving solutions
In order to increase data centers' efficiency and performance, a proper cooling system
should be applied. This article provides a comprehensive assessment which explores …
should be applied. This article provides a comprehensive assessment which explores …
A critical review on the thermal management of data center for local hotspot elimination
R Zhao, Y Du, X Yang, Z Zhou, W Wang, X Yang - Energy and Buildings, 2023 - Elsevier
The data centers consume a significant amount of energy, with cooling demand accounting
for roughly 40% of the total energy usage. The primary reason for this is the presence of the …
for roughly 40% of the total energy usage. The primary reason for this is the presence of the …
Phase change cooling in data centers: A review
With the advent of big data era, data centers (DCs) related energy use accounts for
approximately 3% of the global electric power consumption. As the augmentation of data …
approximately 3% of the global electric power consumption. As the augmentation of data …
Multi-objective optimization of supply air jet enhancing airflow uniformity in data center using Taguchi/CRITIC/TOPSIS triple method
Z Yang, B Niu, Y Pan, Y Chen - Building and Environment, 2023 - Elsevier
Jet fans have been introduced into under-floor air distribution systems as an active local
measure to reduce hot spot temperatures and improve airflow distribution uniformity in data …
measure to reduce hot spot temperatures and improve airflow distribution uniformity in data …
Optimization of underfloor air distribution systems for data centers based on orthogonal test method: A case study
With the rapid development of cloud computing and artificial intelligence, it has been
increasingly significant to reduce the energy consumption of data centers (DCs) by …
increasingly significant to reduce the energy consumption of data centers (DCs) by …
Multi-objective optimization of supply air jet enhancing airflow uniformity in data center with Taguchi-based grey relational analysis
B Niu, M Shi, Z Zhang, Y Li, Y Cao, S Pan - Building and Environment, 2022 - Elsevier
In most data centers (DCs), hot spots reduce the reliability, durability, and efficiency of server
cooling. The hot spots are mainly attributed to the uneven airflow distribution and the …
cooling. The hot spots are mainly attributed to the uneven airflow distribution and the …
Effects of airflow on the thermal environment and energy efficiency in raised-floor data centers: A review
C **, X Bai, C Yang - Science of The Total Environment, 2019 - Elsevier
Airflow is crucial for air-cooled data centers. Its flow path and distribution influences the
thermal environment and energy efficiency of raised-floor data centers. This paper provides …
thermal environment and energy efficiency of raised-floor data centers. This paper provides …
Optimization of the thermal environment of a small-scale data center in China
X Meng, J Zhou, X Zhang, Z Luo, H Gong, T Gan - Energy, 2020 - Elsevier
In data centers, a large number of IT sever racks with different heat dissipation rates are
arranged in multiple rows, leading to much higher per-unit heat release and therefore more …
arranged in multiple rows, leading to much higher per-unit heat release and therefore more …
Multi-scale modeling and fast inference for thermal environment analysis of air-cooled data center
Both the thermal environment of a data center room and the internal thermal environment of
a server are of great concern, but it is extremely difficult to build and solve full-scale …
a server are of great concern, but it is extremely difficult to build and solve full-scale …