Total skin electron irradiation techniques: a review

T Piotrowski, P Milecki, M Skórska… - Advances in Dermatology …, 2013 - termedia.pl
Total skin electron irradiation (TSEI) has been employed as one of the methods of mycosis
fungoides treatment since the mid-twentieth century. In order to improve the effects and limit …

Clinical implementation of total skin electron beam (TSEB) therapy: a review of the relevant literature

S Diamantopoulos, K Platoni, M Dilvoi, I Nazos… - Physica Medica, 2011 - Elsevier
Total skin electron beam therapy has been in medical service since the middle of the last
century in order to confront rare skin malignancies. Since then various techniques have …

[HTML][HTML] In-vivo dosimetric analysis in total skin electron beam therapy

K Elsayad, C Moustakis, M Simonsen, D Bäcker… - Physics and imaging in …, 2018 - Elsevier
Background and purpose Thermoluminescent dosimetry (TLD) is an important element of
total skin electron beam therapy (TSEBT). In this study, we compare radiation dose …

Review of the results of the in vivo dosimetry during total skin electron beam therapy

G Guidi, G Gottardi, P Ceroni… - Reports of Practical …, 2014 - journals.viamedica.pl
This work reviews results of in vivo dosimetry (IVD) for total skin electron beam (TSEB)
therapy, focusing on new methods, data emerged within 2012. All quoted data are based on …

The rotary dual technique for total skin irradiation in the treatment of mycosis fungoides–a description of the applied method

T Piotrowski, J Malicki - Reports of Practical Oncology and …, 2006 - journals.viamedica.pl
Background The aim of total skin electron irradiation in the therapy of mycosis fungoides is
to obtain total or partial remission of the disease while concurrently lowering the toxicity …

[HTML][HTML] In vivo monitoring of total skin electron dose using optically stimulated luminescence dosimeters

T Kairn, R Wilks, L Yu, C Lancaster… - Reports of Practical …, 2020 - Elsevier
Aim This study retrospectively analysed the results of using optically stimulated radiation
dosimeters (OSLDs) for in vivo dose measurements during total skin electron therapy (TSET …

Development of a real‐time in vivo dosimetry tool for electron beam therapy using a flexible thin film solar cell coated with scintillator powder

S Jeong, S An, YC Kwon, S Pak, W Cheon… - Medical …, 2023 - Wiley Online Library
Purpose A real‐time solar cell based in vivo dosimetry system (SC‐IVD) was developed
using a flexible thin film solar cell and scintillating powder. The present study evaluated the …

A technique for total skin electron therapy (TSET) of an anesthetized pediatric patient

T Kron, G Donahoo, P Lonski… - Journal of Applied …, 2018 - Wiley Online Library
Purpose Total skin electron therapy (TSET) is a technique to treat cutaneous lymphomas.
While TSET is rarely required in pediatric patients, it poses particular problems for the …

Total skin electron beam therapy with rotary dual technique as palliative treatment for mycosis fungoides

T Piotrowski, M Fundowicz, M Pawlaczyk - in vivo, 2018 - iv.iiarjournals.org
Background/Aim: The aim of the study was to retrospectively assess the efficacy and toxicity
of total skin electron beam therapy (TSEBT) in patients with primary cutaneous T-cell …

Patient dose analysis using GafchromicTM EBT3 film: a retrospective study with a four dual-field technique in total skin electron therapy

D Sundaramoorthy… - Asian Pacific Journal of …, 2023 - pmc.ncbi.nlm.nih.gov
Objective: The Six dual-field is the most commonly used treatment technique in total skin
electron therapy (TSET). Because of the prolonged treatment period, the patient may …