Fiber-optic photoacoustic gas sensing: a review
Fiber-optic photoacoustic (PA) sensing has important applications in trace gas detection.
The fiber-optic Fabry-Perot acoustic sensor implemented applying a cantilever is a novel …
The fiber-optic Fabry-Perot acoustic sensor implemented applying a cantilever is a novel …
[HTML][HTML] High-sensitivity trace gas detection based on differential Helmholtz photoacoustic cell with dense spot pattern
C Zhang, Y He, S Qiao, Y Liu, Y Ma - Photoacoustics, 2024 - Elsevier
A high-sensitivity photoacoustic spectroscopy (PAS) sensor based on differential Helmholtz
photoacoustic cell (DHPAC) with dense spot pattern is reported in this paper for the first time …
photoacoustic cell (DHPAC) with dense spot pattern is reported in this paper for the first time …
Multi-component Freon gas detection based on infrared tunable Fabry-Perot detector
A multi-component Freon gas sensing system was developed based on the non-dispersive
infrared (NDIR) spectroscopy, which had the advantages of simple structure and low cost …
infrared (NDIR) spectroscopy, which had the advantages of simple structure and low cost …
Simultaneous detection of major greenhouse gases with multiresonator photoacoustic spectroscopy
J Peng, Y Cao, R Wang, G Wang, J Mei, K Liu… - Analytical …, 2024 - ACS Publications
Greenhouse gas (GHG) detection plays an important role in climate change research and
industry applications. A novel photoacoustic spectroscopy (PAS) sensor based on multiple …
industry applications. A novel photoacoustic spectroscopy (PAS) sensor based on multiple …
Photoacoustic spectroscopy based on vertical cruciform multi-stepped photoacoustic cell achieving ppb-level acetylene detection
S Xu, Q Wang, Z Zhu, J Wang, X Zou, Z Li… - Sensors and Actuators B …, 2024 - Elsevier
A photoacoustic spectroscopy (PAS) based on vertical cruciform multi-stepped
photoacoustic cell (CMS-PAC) was developed to achieve highly sensitive detection of trace …
photoacoustic cell (CMS-PAC) was developed to achieve highly sensitive detection of trace …
Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell
H Wang, Y Xu, J Zhang, X Zhao, Z Zhang… - Analytical …, 2025 - ACS Publications
A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is
proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic …
proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic …
Ultratrace CO/SF6 Detection System Based on Differential Fourier Transform Infrared Spectroscopy Combined with the Weighted Sine Spectral Reconstruction …
J Gao, Y Zhang, R Zhu, M Li, F **e, Y Wu… - Analytical …, 2024 - ACS Publications
Carbon monoxide (CO), as an indicator gas for fault diagnosis of gas-insulated switchgear,
has the strongest absorption coefficient in the mid-infrared region, making Fourier transform …
has the strongest absorption coefficient in the mid-infrared region, making Fourier transform …
Highly sensitive CH4-TDLAS sensor based on 3D-printed multi-pass cell
Y Liu, X Sun, H Sun, S Qiao, Y He, Y Ma - Infrared Physics & Technology, 2024 - Elsevier
In this paper, a highly sensitive methane (CH 4) sensor based on tunable diode laser
absorption spectroscopy (TDLAS) with 3D-printed multi-pass cell (MPC) is reported. A MPC …
absorption spectroscopy (TDLAS) with 3D-printed multi-pass cell (MPC) is reported. A MPC …
Fiber-Optic Photoacoustic Gas Microsensor Dual Enhanced by Helmholtz Resonator and Interferometric Cantilever
A high-sensitivity fiber-optic photoacoustic (PA) gas microsensor is demonstrated with dual
enhancement based on acoustics and detection. Due to the characteristic of small size, a …
enhancement based on acoustics and detection. Due to the characteristic of small size, a …
Influence of water vapor concentration on photoacoustic spectroscopy‐based characteristic gas analysis of transformer faults
B Mo, S Zhou, M Han, P **e, C Li, X Han… - Microwave and …, 2024 - Wiley Online Library
The water vapor in the ambient air affects the accuracy of the photoacoustic (PA) dissolved
gas analysis system for transformer health monitoring. A laser PA system was evaluated by …
gas analysis system for transformer health monitoring. A laser PA system was evaluated by …