Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis

C Robba, G Santori, M Czosnyka, F Corradi… - Intensive care …, 2018 - Springer
Purpose Although invasive intracranial devices (IIDs) are the gold standard for intracranial
pressure (ICP) measurement, ultrasonography of the optic nerve sheath diameter (ONSD) …

[HTML][HTML] Intracranial pressure monitoring: Gold standard and recent innovations

DS Nag, S Sahu, A Swain, S Kant - World journal of clinical cases, 2019 - ncbi.nlm.nih.gov
Intracranial pressure monitoring (ICP) is based on the doctrine proposed by Monroe and
Kellie centuries ago. With the advancement of technology and science, various invasive and …

Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study

C Robba, D Cardim, T Tajsic, J Pietersen… - PLoS …, 2017 - journals.plos.org
Background The invasive nature of the current methods for monitoring of intracranial
pressure (ICP) has prevented their use in many clinical situations. Several attempts have …

Invasive and noninvasive means of measuring intracranial pressure: a review

X Zhang, JE Medow, BJ Iskandar, F Wang… - Physiological …, 2017 - iopscience.iop.org
Measurement of intracranial pressure (ICP) can be invaluable in the management of
critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain …

Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement

KB Evensen, PK Eide - Fluids and Barriers of the CNS, 2020 - Springer
Sixty years have passed since neurosurgeon Nils Lundberg presented his thesis about
intracranial pressure (ICP) monitoring, which represents a milestone for its clinical …

Multimodal non-invasive assessment of intracranial hypertension: an observational study

C Robba, S Pozzebon, B Moro, JL Vincent, J Creteur… - Critical Care, 2020 - Springer
Background Although placement of an intra-cerebral catheter remains the gold standard
method for measuring intracranial pressure (ICP), several non-invasive techniques can …

pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring

N Canac, K Jalaleddini, SG Thorpe… - Fluids and Barriers of …, 2020 - Springer
Measurement of intracranial pressure (ICP) is crucial in the management of many
neurological conditions. However, due to the invasiveness, high cost, and required expertise …

Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury

MS Sekhon, DE Griesdale, C Robba… - Intensive care …, 2014 - Springer
Purpose Assess the relationship between optic nerve sheath diameter (ONSD) measured on
bedside portable computed tomography (CT) scans and simultaneously measured …

Idiopathic intracranial hypertension

AK Ball, CE Clarke - The Lancet Neurology, 2006 - thelancet.com
Idiopathic intracranial hypertension is common in obese women and can lead to significant
visual impairment. First described more than 100 years ago, the cause of the disorder …

Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging

J Bäuerle, F Schuchardt, L Schroeder, K Egger… - BMC neurology, 2013 - Springer
Background Quantification of the optic nerve sheath diameter (ONSD) by transbulbar
sonography is a promising non-invasive technique for the detection of altered intracranial …