[HTML][HTML] Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive review

F Scardulla, G Cosoli, S Spinsante, A Poli, G Iadarola… - Measurement, 2023 - Elsevier
Healthcare is expected to increasingly shift care out of inpatient settings thanks to wearable
monitoring systems. Photoplethysmography (PPG) is an optical technique already integrated …

Recent developments in instrumentation of functional near-infrared spectroscopy systems

M Althobaiti, I Al-Naib - Applied Sciences, 2020 - mdpi.com
In the last three decades, the development and steady improvement of various optical
technologies at the near-infrared region of the electromagnetic spectrum has inspired a …

A 119dB dynamic range charge counting light-to-digital converter for wearable PPG/NIRS monitoring applications

Q Lin, J Xu, S Song, A Breeschoten… - … Circuits and Systems, 2020 - ieeexplore.ieee.org
This paper presents a low power, high dynamic range (DR), reconfigurable light-to-digital
converter (LDC) for photoplethysmogram (PPG), and near-infrared spectroscopy (NIRS) …

Evaluation of resonant scanning as a high-speed imaging technique for two-photon imaging of cortical vasculature

A Zhou, SA Engelmann, SA Mihelic, A Tomar… - Biomedical Optics …, 2022 - opg.optica.org
We demonstrate a simple, low-cost two-photon microscope design with both galvo-galvo
and resonant-galvo scanning capabilities. We quantify and compare the signal-to-noise …

Fiberless, multi-channel fNIRS-EEG system based on silicon photomultipliers: towards sensitive and ecological map** of brain activity and neurovascular coupling

AM Chiarelli, D Perpetuini, P Croce, G Greco… - Sensors, 2020 - mdpi.com
Portable neuroimaging technologies can be employed for long-term monitoring of
neurophysiological and neuropathological states. Functional Near-Infrared Spectroscopy …

Time Of Flight measurements via two LiDAR systems with SiPM and APD

G Adamo, A Busacca - 2016 AEIT International Annual …, 2016 - ieeexplore.ieee.org
In this paper, we present an experimental comparison of two LiDAR systems, employing the
SiPM and the APD as photodetectors, in terms of TOF measurements differing for the …

Optimizing sensitivity and dynamic range of silicon photomultipliers for frequency-domain near infrared spectroscopy

VJ Kitsmiller, C Campbell… - Biomedical Optics Express, 2020 - opg.optica.org
Diffuse optical imaging and tomography based upon frequency-domain near-infrared
spectroscopy (fdNIRS) is used to noninvasively measure tissue structure and function …

Evaluation of silicon photomultipliers for multiphoton and laser scanning microscopy

MG Giacomelli - Journal of Biomedical Optics, 2019 - spiedigitallibrary.org
The silicon photomultiplier (SIPM) is an emerging detector technology that enables both
high sensitivity and high dynamic range detection of visible and near-infrared light at a …

PPG embedded system for blood pressure monitoring

D Agrò, R Canicattì, A Tomasino… - 2014 AEIT Annual …, 2014 - ieeexplore.ieee.org
In this work, we have designed and implemented a microcontroller-based embedded system
for blood pressure monitoring through a PhotoPlethysmoGraphic (PPG) technique. In our …

Laser remote magnetometry using mesospheric sodium

TJ Kane, PD Hillman, CA Denman… - Journal of …, 2018 - Wiley Online Library
We have demonstrated a remote magnetometer based on sodium atoms in the Earth's
mesosphere, at a 106‐km distance from our instrument. A 1.33‐watt laser illuminated the …