RF-induced heating of interventional devices at 23.66 MHz
Objective Low-field MRI systems are expected to cause less RF heating in conventional
interventional devices due to lower Larmor frequency. We systematically evaluate RF …
interventional devices due to lower Larmor frequency. We systematically evaluate RF …
An improved intraoral transverse loop coil design for high‐resolution dental MRI
Purpose To improve intraoral transverse loop coil design for high‐resolution dental MRI.
Methods The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlap** …
Methods The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlap** …
Effect of Strain Relief Loop Position on the RF-Induced Heating of Active Implantable Medical Devices at 1.5-T MRI
This article studies the impact of strain relief loops on RF-induced heating of active
implantable medical devices (AIMDs) during magnetic resonance imaging (MRI) scans at …
implantable medical devices (AIMDs) during magnetic resonance imaging (MRI) scans at …
Wirelessly interfacing sensor‐equipped implants and MR scanners for improved safety and imaging
B Silemek, F Seifert, J Petzold, R Brühl… - Magnetic …, 2023 - Wiley Online Library
Purpose To investigate a novel reduced RF heating method for imaging in the presence of
active implanted medical devices (AIMDs) which employs a sensor‐equipped implant that …
active implanted medical devices (AIMDs) which employs a sensor‐equipped implant that …
[HTML][HTML] Radio-frequency induced heating of intra-cranial EEG electrodes: The more the colder?
T Lottner, S Reiss, SB Rieger, M Schuettler, J Fischer… - Neuroimage, 2022 - Elsevier
Many neurological disorders are analyzed and treated with implantable electrodes. Many
patients with such electrodes have to undergo MRI examinations–often unrelated to their …
patients with such electrodes have to undergo MRI examinations–often unrelated to their …
Comparative Study of RF Heating in Deep Brain Stimulation Devices During MRI at 1.5 T and 0.55 T: Challenging the Assumption of Safety at Low Field Strengths
Purpose: Low-field MRI has been assumed to be implant-friendly based on limited studies.
However, RF-induced heating due to an implant is a complex resonance phenomenon …
However, RF-induced heating due to an implant is a complex resonance phenomenon …
On the Validity of the AIMD Transfer Function Model Developed Over Different Implantation Trajectories
The transfer function (TF) method is crucial in assessing radio frequency induced heating in
active implantable medical devices (AIMDs) during magnetic resonance imaging scans …
active implantable medical devices (AIMDs) during magnetic resonance imaging scans …
MR Safety of Inductively Coupled and Conventional Intraoral Coils
AS Tesfai, S Reiss, T Lottner, M Bock… - Investigative …, 2023 - journals.lww.com
Purpose Intraoral coils (IOCs) in magnetic resonance imaging (MRI) significantly improve
the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of …
the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of …
A cascaded heterogeneous equivalent network for evaluating RF-induced hazards on active implantable medical devices
This article presents a cascaded heterogeneous equivalent network for the evaluation of
radiofrequency (RF) induced safety hazards on electrically long active implantable medical …
radiofrequency (RF) induced safety hazards on electrically long active implantable medical …
MR safety assessments of active implantable and interventional devices in a single measurement setup
AC Özen, S Reiss, O Lottner, T Yildirim… - Proc Intl Soc Mag …, 2021 - archive.ismrm.org
Interventional devices such as actively visualized catheters or guidewires have a long
conductive line between the source and the probe at the tip. Long conductive wires can …
conductive line between the source and the probe at the tip. Long conductive wires can …