[HTML][HTML] Quantitative T1 map** using multi-slice multi-shot inversion recovery EPI

RMS Panchuelo, O Mougin, R Turner, ST Francis - NeuroImage, 2021 - Elsevier
An efficient multi-slice inversion–recovery EPI (MS-IR-EPI) sequence for fast, high spatial
resolution, quantitative T 1 map** is presented, using a segmented simultaneous multi …

Unveiling the Effects of Rare-Earth Substitutions on the Structure, Mechanical, Optical, and Imaging Features of ZrO2 for Biomedical Applications

K Srigurunathan, R Meenambal, A Guleria… - ACS Biomaterials …, 2019 - ACS Publications
The impact of selective rare-earth (RE) additions in ZrO2-based ceramics on the resultant
crystal structure, mechanical, morphological, optical, magnetic, and imaging contrast …

Quantitative MRI of diffuse liver diseases: techniques and tissue-mimicking phantoms

A Tipirneni-Sajja, S Brasher, U Shrestha… - … Resonance Materials in …, 2023 - Springer
Quantitative magnetic resonance imaging (MRI) techniques are emerging as non-invasive
alternatives to biopsy for assessment of diffuse liver diseases of iron overload, steatosis and …

PETER PHAN: An MRI phantom for the optimisation of radiomic studies of the female pelvis

L Bianchini, F Botta, D Origgi, S Rizzo, M Mariani… - Physica Medica, 2020 - Elsevier
Purpose To develop a phantom for methodological radiomic investigation on Magnetic
Resonance (MR) images of female patients affected by pelvic cancer. Methods A pelvis …

Fast bound and pore water map** of cortical bone with arbitrary slice oriented two‐dimensional ultra‐short echo time

KD Harkins, T Ketsiri, JS Nyman… - Magnetic resonance in …, 2023 - Wiley Online Library
Purpose Extend fast, two‐dimensional (2D) methods of bound and pore water map** in
bone to arbitrary slice orientation. Methods To correct for slice profile artifacts caused by …

3D printed phantoms mimicking cortical bone for the assessment of ultrashort echo time magnetic resonance imaging

R Rai, D Manton, MG Jameson, S Josan… - Medical …, 2018 - Wiley Online Library
Purpose Human cortical bone has a rapid decay, and it can be visualized using ultrashort
echo time (UTE) techniques in magnetic resonance imaging (MRI). These sequences …

Reproducible phantom for quality assurance in abdominal MRI focussing kidney imaging

M Wolf, S Kommer, S Fembek, U Dröszler… - Frontiers in …, 2022 - frontiersin.org
Quality assurance (QA) in magnetic resonance imaging (MRI) requires test
objects.'Phantoms' provided by MR manufacturers are homogeneously filled spheres or …

Radiation dam** at clinical field strength: Characterization and compensation in quantitative measurements

N Wallstein, R Müller, A Pampel… - Magnetic Resonance in …, 2024 - Wiley Online Library
Purpose In any MR experiment, the bulk magnetization acts on itself, caused by the induced
current in the RF receiver circuit that generates an oscillating dam** field. This effect …

[HTML][HTML] Thermal characterization of phantoms used for quality assurance of deep hyperthermia systems

L Farina, K Sumser, G van Rhoon, S Curto - Sensors, 2020 - mdpi.com
Tissue mimicking phantoms are frequently used in hyperthermia applications for device and
protocol optimization. Unfortunately, a commonly experienced limitation is that their precise …

T1 and T2 and complex permittivities of mineral oil, silicone oil, and glycerol at 0.35, 1.5, and 3 T

HM Gach - Medical physics, 2019 - Wiley Online Library
Purpose To identify an inexpensive, low‐dielectric liquid for large magnetic resonance
imaging (MRI) phantoms that can be used at multiple magnetic field strengths. Methods The …