Tumor tracking method based on a deformable 4D CT breathing motion model driven by an external surface surrogate
Purpose To develop a tumor tracking method based on a surrogate-driven motion model,
which provides noninvasive dynamic localization of extracranial targets for the …
which provides noninvasive dynamic localization of extracranial targets for the …
The markerless lung target tracking AAPM Grand Challenge (MATCH) results
Purpose Lung stereotactic ablative body radiotherapy (SABR) is a radiation therapy success
story with level 1 evidence demonstrating its efficacy. To provide real‐time respiratory …
story with level 1 evidence demonstrating its efficacy. To provide real‐time respiratory …
A Bayesian approach for three-dimensional markerless tumor tracking using kV imaging during lung radiotherapy
The ability to monitor tumor motion without implanted markers can potentially enable broad
access to more accurate and precise lung radiotherapy. A major challenge is that kilovoltage …
access to more accurate and precise lung radiotherapy. A major challenge is that kilovoltage …
RealDRR–rendering of realistic digitally reconstructed radiographs using locally trained image-to-image translation
Abstract Introduction Digitally reconstructed radiographs (DRRs) represent valuable patient-
specific pre-treatment training data for tumor tracking algorithms. However, using current …
specific pre-treatment training data for tumor tracking algorithms. However, using current …
Decompose kV projection using neural network for improved motion tracking in paraspinal SBRT
Purpose On‐treatment kV images have been used in tracking patient motion. One challenge
of markerless motion tracking in paraspinal SBRT is the reduced contrast when the X‐ray …
of markerless motion tracking in paraspinal SBRT is the reduced contrast when the X‐ray …
Markerless tumor tracking using fast‐kV switching dual‐energy fluoroscopy on a benchtop system
M Haytmyradov, H Mostafavi, A Wang, L Zhu… - Medical …, 2019 - Wiley Online Library
Purpose To evaluate markerless tumor tracking (MTT) using fast‐kV switching dual‐energy
(DE) fluoroscopy on a bench top system. Methods Fast‐kV switching DE fluoroscopy was …
(DE) fluoroscopy on a bench top system. Methods Fast‐kV switching DE fluoroscopy was …
Markerless tracking of small lung tumors for stereotactic radiotherapy
JR van Sörnsen de Koste, M Dahele… - Medical …, 2015 - Wiley Online Library
Purpose:(1) To validate retrospective markerless tracking software for small lung tumors by
comparing tracked motion in 4‐dimensional planning computed tomography (4DCT) derived …
comparing tracked motion in 4‐dimensional planning computed tomography (4DCT) derived …
A new scheme for real-time high-contrast imaging in lung cancer radiotherapy: a proof-of-concept study
Visualization of anatomy in real time is of critical importance for motion management in lung
cancer radiotherapy. To achieve real-time, and high-contrast in-treatment imaging, we …
cancer radiotherapy. To achieve real-time, and high-contrast in-treatment imaging, we …
Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy
The ability to monitor tumor motion without implanted markers is clinically advantageous for
lung image-guided radiotherapy (IGRT). Existing markerless tracking methods often suffer …
lung image-guided radiotherapy (IGRT). Existing markerless tracking methods often suffer …
Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold
C Hazelaar, M Dahele, H Mostafavi… - Physics in Medicine …, 2018 - iopscience.iop.org
Lung tumors treated in breath-hold are subject to inter-and intra-breath-hold variations,
which makes tumor position monitoring during each breath-hold important. A markerless …
which makes tumor position monitoring during each breath-hold important. A markerless …