Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Influence of the return stroke current waveform on the lightning performance of distribution lines
An accurate evaluation of the lightning performance of overhead power distribution lines,
that is, the evaluation of the expected number of annual flashovers, can be obtained by the …
that is, the evaluation of the expected number of annual flashovers, can be obtained by the …
Lightning performance assessment of power distribution lines by means of stratified sampling Monte Carlo method
This paper proposes the application of a recursive stratified sampling technique for
improving the assessment of the lightning performance of power distribution lines through …
improving the assessment of the lightning performance of power distribution lines through …
The effect of wide band modeling of tower-footing grounding system on the lightning performance of transmission lines: A probabilistic evaluation
This paper presents a probabilistic evaluation, based on Monte-Carlo method, to estimate
back flashover rate (BFR) and shielding failure flashover rate (SFFOR) of overhead …
back flashover rate (BFR) and shielding failure flashover rate (SFFOR) of overhead …
Impact of grounding modeling on lightning-induced voltages evaluation in distribution lines
Lightning-induced voltages are one of the main causes of shutdown in distribution lines. In
this work, attention is focused on the effects of wideband modeling of electric grounding in …
this work, attention is focused on the effects of wideband modeling of electric grounding in …
Lightning-induced voltages on a distribution line with surge arresters using a hybrid FDTD–SPICE method
H Chen, Y Du, M Yuan, QH Liu - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Installing lightning arresters is an effective way to protect distribution lines from lightning-
induced voltages. Spacing effectiveness of lightning arresters is one of the main concerns in …
induced voltages. Spacing effectiveness of lightning arresters is one of the main concerns in …
Lightning protection of overhead distribution lines installed on high resistivity soil
The paper presents a comprehensive study on the lightning performance of overhead
distribution lines located on high resistivity soil considering both indirect and direct strokes …
distribution lines located on high resistivity soil considering both indirect and direct strokes …
Exact expressions for lightning electromagnetic fields: application to the Rusck field-to-transmission line coupling model
An exact analytical expression for the electric field of the return stroke as excited by a
propagating step current source is derived in this paper. This expression could be …
propagating step current source is derived in this paper. This expression could be …
Computation of peak lightning-induced voltages due to the typical first and subsequent strokes considering high ground resistivity
It is essential that the insulation system of the overhead distribution lines should be properly
designed to ensure their immunity against lightning-induced overvoltages (LIOVs) caused …
designed to ensure their immunity against lightning-induced overvoltages (LIOVs) caused …
Assessment of the Lightning Performance of overhead distribution lines based on Lightning Location Systems data
M Nicora, D Mestriner, M Brignone, M Bernardi… - International Journal of …, 2022 - Elsevier
This article presents the Lightning Performance (LP) assessment of a realistic portion of the
Italian distribution network with the use of probability distributions for lightning parameters …
Italian distribution network with the use of probability distributions for lightning parameters …
Effect of high-resistivity ground on the lightning performance of overhead lines
This paper presents an approximate formula for the peak-value of the lightning overvoltages
induced on aerial lines installed over high resistivity ground, which is valid up to 10 kΩ m …
induced on aerial lines installed over high resistivity ground, which is valid up to 10 kΩ m …