Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] In-vivo microsystems: a review
In-vivo sensors yield valuable medical information by measuring directly on the living tissue
of a patient. These devices can be surface or implant devices. Electrical activity in the body …
of a patient. These devices can be surface or implant devices. Electrical activity in the body …
An improved FSK-modulated class-E power and data transmitter for biomedical implants
This paper presents an efficient dual-resonance biomedical inductive link for frequency-shift
keying (FSK) modulation. In this link, the combination of PCB coil as the main coil and the …
keying (FSK) modulation. In this link, the combination of PCB coil as the main coil and the …
A 74-μW 11-Mb/s Wireless Vital Signs Monitoring SoC for Three-Lead ECG, Respiration Rate, and Body Temperature
This paper presents a wireless vital signs monitoring system-on-chip including three-lead
ECG, bio-impedance (Bio-Z) and body temperature. A Bio-Z readout channel with early …
ECG, bio-impedance (Bio-Z) and body temperature. A Bio-Z readout channel with early …
Design of 8-bit low power SAR ADC in 45 nm for biomedical implants
The utilisation of low power SAR (Successive Approximation Register) Analog-to-Digital
Converters holds significant importance in the domain of bio-medical signal acquisition. The …
Converters holds significant importance in the domain of bio-medical signal acquisition. The …
A 300 Mbps 37 pJ/bit pulsed optical biotelemetry
This article reports an implantable transcutaneous telemetry for a brain machine interface
that uses a novel optical communication system to achieve a highly energy-efficient link …
that uses a novel optical communication system to achieve a highly energy-efficient link …
Wirelessly powered, batteryless closed-loop biopotential recording IC for implantable leadless cardiac monitoring applications
This paper reports on a low-power biopotential recording IC (Integrated circuit) for an
implantable leadless cardiac monitoring application. The IC is designed to realize fully …
implantable leadless cardiac monitoring application. The IC is designed to realize fully …
A low-power single-path bio-impedance measurement system using an analog-to-digital converter for i/q demodulation
In this paper, a low power single-path bio-impedance (Bio-Z) measurement system for early
detection of acute myocardial ischemia is presented. The fully integrated system consists of …
detection of acute myocardial ischemia is presented. The fully integrated system consists of …
A class-E power and data transmitter with improved data rate to carrier frequency ratio for medical implants
In this brief, a new wireless power transfer and data telemetry circuit for biomedical implants
is proposed that increases the data-rate without compromising power transmission …
is proposed that increases the data-rate without compromising power transmission …
High-Performance Wireless Power and Data Transmission System for Medical Implant Devices Using ASK Modulation
H Zhu, M Tahir, X Wu, S Hu - Energies, 2024 - mdpi.com
Wireless power and data transmission (WPDT) solutions for medical implants are highly
desired. However, achieving a high-power transmission efficiency and data rate …
desired. However, achieving a high-power transmission efficiency and data rate …
A 4.5 W Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System
This article presents a chip designed for wireless intra-cardiac monitoring systems. The
design consists of a three-channel analog front-end, a pulse-width modulator featuring …
design consists of a three-channel analog front-end, a pulse-width modulator featuring …