Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Initial recommendations for performing, benchmarking and reporting single-cell proteomics experiments
Analyzing proteins from single cells by tandem mass spectrometry (MS) has recently
become technically feasible. While such analysis has the potential to accurately quantify …
become technically feasible. While such analysis has the potential to accurately quantify …
Electrospray ionization mass spectrometry: a technique to access the information beyond the molecular weight of the analyte
The Electrospray Ionization (ESI) is a soft ionization technique extensively used for
production of gas phase ions (without fragmentation) of thermally labile large …
production of gas phase ions (without fragmentation) of thermally labile large …
An overview of matrix effects in liquid chromatography–mass spectrometry
H Trufelli, P Palma, G Famiglini… - Mass spectrometry …, 2011 - Wiley Online Library
Matrix‐dependent signal suppression or enhancement represents a major drawback in
quantitative analysis with liquid chromatography coupled to atmospheric pressure ionization …
quantitative analysis with liquid chromatography coupled to atmospheric pressure ionization …
[BOG][B] Mass spectrometry: a textbook
JH Gross - 2006 - books.google.com
When non-mass spectrometrists are talking about mass spectrometry it rather often sounds
as if they were telling a story out of Poe's Tales of Mystery and Imagi-tion. Indeed, mass …
as if they were telling a story out of Poe's Tales of Mystery and Imagi-tion. Indeed, mass …
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
P Kebarle - Journal of mass spectrometry, 2000 - Wiley Online Library
A brief account of the mechanisms by which ions in solution are converted to ions in the gas
phase is given on the basis of information available in the literature and the four companion …
phase is given on the basis of information available in the literature and the four companion …
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
R Kostiainen, TJ Kauppila - Journal of Chromatography A, 2009 - Elsevier
The most widely used ionization techniques in liquid chromatography–mass spectrometry
(LC–MS) are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) …
(LC–MS) are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) …
Ion formation mechanisms in UV-MALDI
R Knochenmuss - Analyst, 2006 - pubs.rsc.org
Matrix Assisted Laser Desorption/Ionization (MALDI) is a very widely used analytical
method, but has been developed in a highly empirical manner. Deeper understanding of …
method, but has been developed in a highly empirical manner. Deeper understanding of …
Mechanism of charging and supercharging molecules in electrospray ionization
AT Iavarone, ER Williams - Journal of the American Chemical …, 2003 - ACS Publications
The origin of the extent of charging and the mechanism by which multiply charged ions are
formed in electrospray ionization have been hotly debated for over a decade. Many factors …
formed in electrospray ionization have been hotly debated for over a decade. Many factors …
Internal energy and fragmentation of ions produced in electrospray sources
This review addresses the determination of the internal energy of ions produced by
electrospray ionization (ESI) sources, and the influence of the internal energy on analyte …
electrospray ionization (ESI) sources, and the influence of the internal energy on analyte …
Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry
A droplet pickup and other mechanisms have been suggested for the ionization of
biomolecules like peptides and proteins by desorption electrospray ionization. To verify this …
biomolecules like peptides and proteins by desorption electrospray ionization. To verify this …