[HTML][HTML] The EMBRACE II study: The outcome and prospect of two decades of evolution within the GEC-ESTRO GYN working group and the EMBRACE studies

R Pötter, K Tanderup, C Kirisits, A de Leeuw… - Clinical and translational …, 2018 - Elsevier
The publication of the GEC-ESTRO recommendations one decade ago was a significant
step forward for reaching international consensus on adaptive target definition and dose …

Uncertainties in volume delineation in radiation oncology: a systematic review and recommendations for future studies

SK Vinod, MG Jameson, M Min, LC Holloway - Radiotherapy and Oncology, 2016 - Elsevier
Background and purpose Volume delineation is a well-recognised potential source of error
in radiotherapy. Whilst it is important to quantify the degree of interobserver variability (IOV) …

[HTML][HTML] IBS-GEC ESTRO-ABS recommendations for CT based contouring in image guided adaptive brachytherapy for cervical cancer

U Mahantshetty, R Poetter, S Beriwal, S Grover… - Radiotherapy and …, 2021 - Elsevier
MR Imaging is regarded as the gold standard for Image Gudied Adaptive Brachytherapy
(IGABT) for cervical cancer. However, its wide applicability is limited by its availability …

Risk factors for local failure following chemoradiation and magnetic resonance image–guided brachytherapy in locally advanced cervical cancer: results from the …

MP Schmid, JC Lindegaard, U Mahantshetty… - Journal of Clinical …, 2023 - ascopubs.org
PURPOSE To report clinical and treatment characteristics, remission and failure patterns,
and risk factors for local failure (LF) from the EMBRACE-I study. MATERIALS AND …

Comparison and consensus guidelines for delineation of clinical target volume for CT-and MR-based brachytherapy in locally advanced cervical cancer

AN Viswanathan, B Erickson, DK Gaffney… - International Journal of …, 2014 - Elsevier
Objective To create and compare consensus clinical target volume (CTV) contours for
computed tomography (CT) and 3-Tesla (3-T) magnetic resonance (MR) image-based …

Automatic segmentation of magnetic resonance images for high‐dose‐rate cervical cancer brachytherapy using deep learning

SA Yoganathan, SN Paul, S Paloor, T Torfeh… - Medical …, 2022 - Wiley Online Library
Purpose Magnetic resonance (MR) imaging is the gold standard in image‐guided
brachytherapy (IGBT) due to its superior soft‐tissue contrast for target and organs‐at‐risk …

[PDF][PDF] Uncertainties in target volume delineation in radiotherapy–are they relevant and what can we do about them?

B Segedin, P Petric - Radiology and oncology, 2016 - sciendo.com
Background. Modern radiotherapy techniques enable delivery of high doses to the target
volume without escalating dose to organs at risk, offering the possibility of better local control …

Magnetic resonance image guided brachytherapy

K Tanderup, AN Viswanathan, C Kirisits… - Seminars in radiation …, 2014 - Elsevier
The application of magnetic resonance image (MRI)–guided brachytherapy has
demonstrated significant growth during the past 2 decades. Clinical improvements in cervix …

Image-based brachytherapy for the treatment of cervical cancer

MM Harkenrider, F Alite, SR Silva, W Small Jr - International Journal of …, 2015 - Elsevier
Cervical cancer is a disease that requires considerable multidisciplinary coordination of care
and labor in order to maximize tumor control and survival while minimizing treatment-related …

In vivo dosimetry: trends and prospects for brachytherapy

G Kertzscher, A Rosenfeld, S Beddar… - The British journal of …, 2014 - academic.oup.com
The error types during brachytherapy (BT) treatments and their occurrence rates are not well
known. The limited knowledge is partly attributed to the lack of independent verification …