Status and perspectives of hydrogenated amorphous silicon detectors for MIP detection and beam flux measurements

M Menichelli, L Servoli, N Wyrsch - Frontiers in Physics, 2022 - frontiersin.org
Hydrogenated amorphous silicon (a-Si: H) particle detectors have been considered as
alternatives to crystalline silicon detectors (c-Si) in high radiation environments, due to their …

DC response, low-frequency noise, and TID-induced mechanisms in 16-nm FinFETs for high-energy physics experiments

S Bonaldo, T Ma, S Mattiazzo, A Baschirotto… - Nuclear Instruments and …, 2022 - Elsevier
Abstract Total-ionizing-dose (TID) mechanisms are evaluated in 16 nm Si bulk FinFETs at
doses up to 1 Grad (SiO 2) for applications in high-energy physics experiments. The TID …

RD53 pixel chips for the ATLAS and CMS Phase-2 upgrades at HL-LHC

F Loddo, A Andreazza, F Arteche, MB Barbero… - Nuclear Instruments and …, 2024 - Elsevier
The Phase-2 upgrades at the High-Luminosity LHC of ATLAS and CMS experiments at
CERN will require a new tracker with readout electronics operating in extremely harsh …

BDAQ53, a versatile pixel detector readout and test system for the ATLAS and CMS HL-LHC upgrades

M Daas, Y Dieter, J Dingfelder, M Frohne… - Nuclear Instruments and …, 2021 - Elsevier
BDAQ53 is a readout system and verification framework for hybrid pixel detector readout
chips of the RD53 family. These chips are designed for the upgrade of the inner tracking …

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

W Adam, T Bergauer, D Blöch… - Journal of …, 2021 - iopscience.iop.org
A: The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to
the start of the High Luminosity LHC period. One of the crucial components of the new Inner …

The CMS tracker for the high luminosity LHC

A Rossi, CMS Collaboration - … and Methods in Physics Research Section …, 2023 - Elsevier
The LHC machine is planning an upgrade program which will smoothly bring the
instantaneous luminosity to about 5–7.5× 1 0 34 cm− 2 s− 1, to reach an integrated …

28 nm CMOS analog front-end channels for future pixel detectors

L Gaioni, M Fratus, A Galliani, M Manghisoni… - Nuclear instruments and …, 2023 - Elsevier
This work discusses the design, carried out in the framework of the INFN Falaphel project, of
analog front-end circuits for future, high-rate pixel detector applications. In particular, two …

Optimization of the 65-nm CMOS Linear Front-End Circuit for the CMS Pixel Readout at the HL-LHC

L Gaioni, M Manghisoni, L Ratti, V Re… - … on Nuclear Science, 2021 - ieeexplore.ieee.org
The linear front-end is the analog processor chosen for the final integration into the pixel
readout chip for the high-luminosity upgrade of the CMS experiment at the large hadron …

The upgrade of the CMS inner tracker for HL-LHC

M Backhaus - Journal of Instrumentation, 2019 - iopscience.iop.org
Abstract During the Long Shutdown (LS) from 2024 to 2026 the Large Hadron Collider
(LHC) will be upgraded in order to provide a ten-fold increase of the data rate to the …