Report of AAPM task group 235 radiochromic film dosimetry: an update to TG‐55
A Niroomand‐Rad, ST Chiu‐Tsao, MP Grams… - Medical …, 2020 - Wiley Online Library
The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high
level of achievable accuracy for a wide range of dose values and its suitability under a …
level of achievable accuracy for a wide range of dose values and its suitability under a …
Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
S Reinhardt, M Hillbrand, JJ Wilkens… - Medical …, 2012 - Wiley Online Library
Purpose: Dose verification in highly conformal radiation therapy such as IMRT or proton
therapy can benefit from the high spatial resolution offered by radio‐chromic films such as …
therapy can benefit from the high spatial resolution offered by radio‐chromic films such as …
Small-field radiotherapy photon beam output evaluation: Detectors reviewed
Small fields (few cm and below) are being applied in therapy independently or as mm/sub-
cm segments of larger fields. Included are intensity modulated radiotherapy …
cm segments of larger fields. Included are intensity modulated radiotherapy …
A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT
C Andres, A Del Castillo, R Tortosa, D Alonso… - Medical …, 2010 - Wiley Online Library
Purpose: Radiochromic film has become an important tool to assess complex dose
distributions. In particular, EBT was accepted by the scientific community as a reference two …
distributions. In particular, EBT was accepted by the scientific community as a reference two …
Multi‐institution validation of a new high spatial resolution diode array for SRS and SBRT plan pretreatment quality assurance
MS Rose, L Tirpak, K Van Casteren, J Zack… - Medical …, 2020 - Wiley Online Library
Purpose The SRS MapCHECK®, a recently developed patient‐specific quality assurance
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …
Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure
L Menegotti, A Delana, A Martignano - Medical physics, 2008 - Wiley Online Library
Film dosimetry is an attractive tool for dose distribution verification in intensity modulated
radiotherapy (IMRT). A critical aspect of radiochromic film dosimetry is the scanner used for …
radiotherapy (IMRT). A critical aspect of radiochromic film dosimetry is the scanner used for …
Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy
L Richley, AC John, H Coomber… - Physics in Medicine & …, 2010 - iopscience.iop.org
A new radiochromic film, the yellow Gafchromic EBT2, has been marketed as a drop-in
replacement for the discontinued blue EBT film. In order to verify the manufacturer's claims …
replacement for the discontinued blue EBT film. In order to verify the manufacturer's claims …
Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
N Wen, S Lu, J Kim, Y Qin, Y Huang, B Zhao, C Liu… - Radiation …, 2016 - Springer
Purpose The purpose of this study is to evaluate the dosimetric uncertainty associated with
Gafchromic™(EBT3) films and establish a practical and efficient film dosimetry protocol for …
Gafchromic™(EBT3) films and establish a practical and efficient film dosimetry protocol for …
Characterization of a novel two dimensional diode array the “magic plate” as a radiation detector for radiation therapy treatment
Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf
collimators to deliver highly modulated and complex radiation treatment. Dosimetric …
collimators to deliver highly modulated and complex radiation treatment. Dosimetric …
How flatbed scanners upset accurate film dosimetry
LJ Van Battum, H Huizenga… - Physics in Medicine …, 2015 - iopscience.iop.org
How flatbed scanners upset accurate film dosimetry - IOPscience Skip to content IOP Science
home Accessibility Help Search all IOPscience content Search Article Lookup Select journal …
home Accessibility Help Search all IOPscience content Search Article Lookup Select journal …