Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems

D Lakstein, N Eliaz, O Levi, D Backstein, Y Kosashvili… - JBJS, 2011 - journals.lww.com
Background: Mechanical failure of femoral stems at the modular junction of revision hip
arthroplasty systems has been reported only infrequently. In the current study, the cause of …

[HTML][HTML] Femoral stem fracture in hip revision arthroplasty: a systematic literature review of the real-world evidence

M Sukopp, D Taylor, R Forst… - Zeitschrift für Orthopädie …, 2022 - thieme-connect.com
Background Total hip arthroplasty (THA) presents as an excellent treatment for the
osteoarthritic hip, demonstrating good survival rates. However, aseptic loosening and …

Results of revision total hip arthroplasty with modular, titanium-tapered femoral stems in severe proximal metaphyseal and diaphyseal bone loss

BT Palumbo, KL Morrison, AS Baumgarten… - The Journal of …, 2013 - Elsevier
Evidence supporting modular, tapered stems for severe proximal metaphyseal and
diaphyseal bone loss is limited. We report our clinical experience with its use for severely …

Fatigue fracture in dual modular revision total hip arthroplasty stems: failure analysis and computed tomography diagnostics in two cases

P Norman, S Iyengar, I Svensson, G Flivik - The Journal of arthroplasty, 2014 - Elsevier
We report on two patients with fracture of a modular, tapered and distally fixed, uncemented
titanium revision hip stem, not previously described. A failure analysis revealed that the …

Analyses of prosthesis stem failures in noncemented modular hip revision prostheses

T Efe, J Schmitt - The Journal of Arthroplasty, 2011 - Elsevier
In recent years, hip prosthesis stem revision by means of modular revision systems has
reached an essential role in revision prosthetics. It is an extremely successful technique …

Mechanical failure of 113 uncemented modular revision femoral components: risk factors for fracture and failure with a case control comparison analysis

DR Krueger, KP Guenther, MC Deml… - The bone & joint …, 2020 - boneandjoint.org.uk
Aims We evaluated a large database with mechanical failure of a single uncemented
modular femoral component, used in revision hip arthroplasty, as the end point and …

Influence of technique with distally fixed modular stems in revision total hip arthroplasty

PD Patel, AK Klika, TG Murray, KA Elsharkawy… - The Journal of …, 2010 - Elsevier
Distally fixed modular implants have seen a recent increase in use, to manage proximal
femoral bone loss often encountered during revision total hip arthroplasty (THA). Forty-three …

Comparison of fatigue properties and fatigue crack growth rates of various implantable metals

Y Okazaki - Materials, 2012 - mdpi.com
The fatigue strength, effects of a notch on the fatigue strength, and fatigue crack growth rate
of Ti-15Zr-4Nb-4Ta alloy were compared with those of other implantable metals. Zr, Nb, and …

Which length should the neck segment of modular revision stems have?

G Huber, MM Morlock - Clinical biomechanics, 2022 - Elsevier
Background Fractures of modular revision stems at the taper junction are rare but severe
clinical problems. The purpose of this study was the estimation of taper loading to identify …

Clinical, radiographic, and survivorship analysis of a modular fluted tapered stem in revision hip arthroplasty

CHF Picado, A Savarese… - Journal of …, 2019 - journals.sagepub.com
Purpose: Modular fluted tapered stems are one of the most commonly used implants in
femoral revision surgery. Due to the relative lack of studies on the Restoration modular fluted …