Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls
In this paper, the authors review the field of resolution modeling in positron emission
tomography (PET) image reconstruction, also referred to as point‐spread‐function modeling …
tomography (PET) image reconstruction, also referred to as point‐spread‐function modeling …
Monte Carlo techniques in medical radiation physics
P Andreo - Physics in Medicine & Biology, 1991 - iopscience.iop.org
The author's main purpose is to review the techniques and applications of the Monte Carlo
method in medical radiation physics since Raeside's review article in 1976. Emphasis is …
method in medical radiation physics since Raeside's review article in 1976. Emphasis is …
ICRU REPORT 96, dosimetry-guided radiopharmaceutical therapy
The International Commission on Radiation Units and Measurements (ICRU), since its
inception in 1925, has had as its principal objective the development of internationally …
inception in 1925, has had as its principal objective the development of internationally …
[PDF][PDF] PENELOPE-2014: A code system for Monte Carlo simulation of electron and photon transport
D Bank - 2015 - oecd-nea.org
The computer code system penelope (version 2014) performs Monte Carlo simulation of
coupled electron-photon transport in arbitrary materials for a wide energy range, from a few …
coupled electron-photon transport in arbitrary materials for a wide energy range, from a few …
BEAM: a Monte Carlo code to simulate radiotherapy treatment units
This paper describes BEAM, a general purpose Monte Carlo code to simulate the radiation
beams from radiotherapy units including high‐energy electron and photon beams, 60Co …
beams from radiotherapy units including high‐energy electron and photon beams, 60Co …
PENELOPE: an algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter
J Baró, J Sempau, JM Fernández-Varea… - Nuclear Instruments and …, 1995 - Elsevier
A mixed algorithm for Monte Carlo simulation of relativistic electron and positron transport in
matter is described. Cross sections for the different interaction mechanisms are …
matter is described. Cross sections for the different interaction mechanisms are …
Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
I Kawrakow - Medical physics, 2000 - Wiley Online Library
In this report a new egs4 version, called egsnrc to reflect the substantial changes made to
the original code is reported, which incorporates a new any‐angle multiple elastic scattering …
the original code is reported, which incorporates a new any‐angle multiple elastic scattering …
[KİTAP][B] Handbook of radiotherapy physics: theory and practice
P Mayles, A Nahum, JC Rosenwald - 2007 - taylorfrancis.com
From background physics and biological models to the latest imaging and treatment
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …
[PDF][PDF] BEAMnrc users manual
DWO Rogers, B Walters, I Kawrakow - Nrc Report Pirs, 2009 - nrc-cnrc.github.io
Abstract BEAMnrc is a Monte Carlo simulation system (Med. Phys. 22, 1995, 503–524) for
modelling radiotherapy sources which was developed as part of the OMEGA project to …
modelling radiotherapy sources which was developed as part of the OMEGA project to …
Fifty years of Monte Carlo simulations for medical physics
DWO Rogers - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …