Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Monte Carlo simulation of a medical linear accelerator for generation of phase spaces
ACH Oliveira, MG Santana, FRA Lima, JW Vieira - 2013 - inis.iaea.org
Radiotherapy uses various techniques and equipment for local treatment of cancer. The
equipment most often used in radiotherapy to the patient irradiation are linear accelerators …
equipment most often used in radiotherapy to the patient irradiation are linear accelerators …
Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
The capabilities of the personal computers allow the application of Monte Carlo methods to
simulate very complex problems that involve the transport of particles through matter. Among …
simulate very complex problems that involve the transport of particles through matter. Among …
Study of CdTe detector response functions using different MCNPX computational modeling detailing
The spectra measured with cadmium telluride (CdTe) detectors show high spectral
distortions that must be corrected by applying a mathematical algorithm along with the …
distortions that must be corrected by applying a mathematical algorithm along with the …
Implementação de fantoma geométrico de mão e antebraço no código de Monte Carlo Geant4
PR Pessanha, PP de Queiroz Filho… - Brazilian Journal of …, 2015 - bjrs.org.br
Anualmente, diversos radiofármacos são utilizados em mais de 50 procedimentos clínicos
diferentes em todo o Brasil. Sendo assim, profissionais inseridos nas diversas práticas de …
diferentes em todo o Brasil. Sendo assim, profissionais inseridos nas diversas práticas de …
Implementation of mathematical phantom of hand and forearm in GEANT4 Monte Carlo code
PR Pessanha, PP Queiroz Filho, DS Santos - inis.iaea.org
Anualmente, diversos radiofármacos são utilizados em mais de 50 procedimentos clínicos
diferentes em todo Brasil. Sendo assim, profissionais inseridos nas diversas práticas de …
diferentes em todo Brasil. Sendo assim, profissionais inseridos nas diversas práticas de …
Simulation of extremities exposure to 1'8F in procedures of positron emission tomography
PR Pessanha - inis.iaea.org
[en] This work was done with the dosimetry of a geometric hand phantom, with Geant4
Monte Carlo code, representing the occupationally exposed individual (OEI) in nuclear …
Monte Carlo code, representing the occupationally exposed individual (OEI) in nuclear …
Detector para raios X usando sensor LDR para mensurar a energia dos fótons emitidos e testar a eficiência de aparelhos hospitalares
ERS Vasconcelos - 2014 - icts.unb.br
A presente pesquisa descreve o estudo com um sensor de LDR desenvolvido para detectar
raios X. Com o sensor, foi possível medir a voltagem produzida pelo sensor quando …
raios X. Com o sensor, foi possível medir a voltagem produzida pelo sensor quando …
[PDF][PDF] COMISSÃO NACIONAL DE ENERGIA NUCLEAR INSTITUTO DE RADIOPROTEÇÃO E DOSIMETRIA COORDENAÇÃO DE PÓS-GRADUAÇÃO
ADAM DO - 2012 - moodle.ird.gov.br
COMISSÃO NACIONAL DE ENERGIA NUCLEAR INSTITUTO DE RADIOPROTEÇÃO E
DOSIMETRIA COORDENAÇÃO DE PÓS-GRADUAÇÃO AVALIAÇÃO DA Page 1 COMISSÃO …
DOSIMETRIA COORDENAÇÃO DE PÓS-GRADUAÇÃO AVALIAÇÃO DA Page 1 COMISSÃO …
[SITAT][C] IMPLEMENTAÇÃO DO SOFTWARE ERX USANDO O MICROSOFT VISUAL STUDIO 2010 EA LINGUAGEM DE PROGRAMAÇÃO C
MOM Cabral, JW Vieira, VL Neto