Challenges and Trends of Implantable Functional Electrical Neural Stimulators: System Architecture and Parameters
Electrical neural stimulators (ENS) play a crucial role in medical applications and have
emerged as promising therapeutic techniques for neurological disorders. The purpose of …
emerged as promising therapeutic techniques for neurological disorders. The purpose of …
Advances in neural recording and stimulation integrated circuits
In the past few decades, driven by the increasing demands in the biomedical field aiming to
cure neurological diseases and improve the quality of daily lives of the patients, researchers …
cure neurological diseases and improve the quality of daily lives of the patients, researchers …
MRC-based double figure-of-eight coil sensor system with triple-mode operation capability for biomedical applications
Efficient wireless power transmission to a designated location can reduce the size of
implantable device and save source energy, but the receiver coil and rectifier circuit still …
implantable device and save source energy, but the receiver coil and rectifier circuit still …
The role and challenges of body channel communication in wearable flexible electronics
Flexible electronics are compatible with film substrates that are soft and stretchable,
resulting in conformal integration with human body. Integrated with various sensors and …
resulting in conformal integration with human body. Integrated with various sensors and …
A blink restoration system with contralateral EMG triggered stimulation and real-time artifact blanking
X Yi, J Jia, S Deng, SG Shen, Q **e… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
Patients suffering from facial paralysis are on the hazard of disfigurement and loss of vision
due to loss of blink function. Functional-electrical stimulation (FES) is one possible way of …
due to loss of blink function. Functional-electrical stimulation (FES) is one possible way of …
A neurostimulator ic with impedance-aware dynamic-precision one-shot charge balancing
This letter presents the design, development, and experimental characterization of a current-
mode neurostimulator IC with a safe one-shot charge imbalance compensation, achieved …
mode neurostimulator IC with a safe one-shot charge imbalance compensation, achieved …
A 0.034% charge-imbalanced neural stimulation front-end (SFE) IC with on-chip voltage compliance monitoring circuit and analysis on resting potential by utilizing the …
The proposed SFE IC adopts an eight-channel H-bridge structure with an integrated voltage
compliance monitoring circuit. It has stimulation current ranged from 0.78 mA to 6.2 mA …
compliance monitoring circuit. It has stimulation current ranged from 0.78 mA to 6.2 mA …
Design of a net-zero charge neural stimulator with feedback control
This paper presents a high efficiency, net-zero charge neural stimulator. A new stimulation
strategy is proposed to reduce the charge error that originates from the irreversible charge …
strategy is proposed to reduce the charge error that originates from the irreversible charge …
Brain-Machine Interface
Brain–machine interfaces (BMIs) create an artificial pathway between the brain and the
external world. BMIs have broad applications in fundamental neuroscience research …
external world. BMIs have broad applications in fundamental neuroscience research …
A 2‐mA charge‐balanced neurostimulator in 0.18‐μm/1.8 V standard CMOS process
This paper presents a programmable neurostimulator 4× VDD with 7.2 V operating voltage
in a 0.18‐μm/1.8 V CMOS process. The output voltage compliance exceeds 6.2 V. A current …
in a 0.18‐μm/1.8 V CMOS process. The output voltage compliance exceeds 6.2 V. A current …