Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Reactive power ancillary service by constant power loads in distributed AC systems
Reactive power is one of the power system ancillary services and can be supplied from
either static or dynamic VAR sources. Provision of reactive power in the proximity of load is …
either static or dynamic VAR sources. Provision of reactive power in the proximity of load is …
Validação experimental de uma microrrede com controle centralizado e despachável
Baseado em uma arquitetura centralizada e despachável, este trabalho demonstra que é
possível operar uma microrrede sob condições de ilhamento ou interconexão, de forma …
possível operar uma microrrede sob condições de ilhamento ou interconexão, de forma …
Loss minimization in AC distribution system with high share of power electronic loads providing ancillary reactive power
N Jelani, M Molinas - 2011 IEEE Trondheim PowerTech, 2011 - ieeexplore.ieee.org
This article proposes a methodology for loss minimization based on the dispersed injection
of reactive current by the power electronic load interfaces. Power flow optimization of the …
of reactive current by the power electronic load interfaces. Power flow optimization of the …
Current control for a grid-connected inverter operating with highly distorted grid voltage
Grid-connected inverters are an essential component of modern photovoltaic systems. They
allow the users to obtain a faster recovery of the investment given their capability of injecting …
allow the users to obtain a faster recovery of the investment given their capability of injecting …
Design of current control loop for grid connected inverters operating under nonideal grid conditions
A case study for designing the current control loop for single-phase inverters connected to
weak grids is presented. The problems associated to the design of current control loop when …
weak grids is presented. The problems associated to the design of current control loop when …
Optimal Operation of a Distributed System with High Share of Power Electronic Loads
N Jelani - 2010 - ntnuopen.ntnu.no
The tendency of connecting the loads to the three phase AC system through power
electronic interfaces is increasing with time. These interfaces greatly affect the performance …
electronic interfaces is increasing with time. These interfaces greatly affect the performance …
Multifunctional shunt compensator for power quality and power flow control for wind generator directly connected to the grid
FN e Braga, JA Pomílio - 2012 IEEE International Energy …, 2012 - ieeexplore.ieee.org
This paper presents a shunt connected power electronics converter, interfacing a wind
generator with a squirrel cage induction generator directly connected to the grid. The …
generator with a squirrel cage induction generator directly connected to the grid. The …
Multifunctional converter for power quality and power flow control in wind distributed generation systems directly connected to the grid
FN Braga, JP Bonaldo… - 2014 11th IEEE/IAS …, 2014 - ieeexplore.ieee.org
This paper presents a shunt-connected converter for interfacing a distributed generation
system and the grid, with focus on uncontrolled small power wind generators. The objective …
system and the grid, with focus on uncontrolled small power wind generators. The objective …