Active power filter (APF) for mitigation of power quality issues in grid integration of wind and photovoltaic energy conversion system

WU Tareen, S Mekhilef, M Seyedmahmoudian… - … and Sustainable Energy …, 2017 - Elsevier
The deep integration of renewable energy resources, including solar photovoltaic (PV) and
wind turbine (WT) energy, mainly depend on the inexpensive technological improvement of …

Mitigation of power quality issues due to high penetration of renewable energy sources in electric grid systems using three-phase APF/STATCOM technologies: A …

WUK Tareen, M Aamir, S Mekhilef, M Nakaoka… - Energies, 2018 - mdpi.com
This study summarizes an analytical review on the comparison of three-phase static
compensator (STATCOM) and active power filter (APF) inverter topologies and their control …

An advanced current control strategy for three-phase shunt active power filters

QN Trinh, HH Lee - IEEE Transactions on Industrial Electronics, 2012 - ieeexplore.ieee.org
This paper proposes an advanced control strategy to enhance performance of shunt active
power filter (APF). The proposed control scheme requires only two current sensors at the …

Predictive torque control scheme for three-phase four-switch inverter-fed induction motor drives with DC-link voltages offset suppression

D Zhou, J Zhao, Y Liu - IEEE Transactions on Power …, 2014 - ieeexplore.ieee.org
The four-switch three-phase (B4) inverter, having a lower number of switches, was first
presented for the possibility of reducing the inverter cost, and it became very attractive as it …

DTC scheme for a four-switch inverter-fed induction motor emulating the six-switch inverter operation

B El Badsi, B Bouzidi… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
This paper proposes a novel direct torque control (DTC) strategy for induction motor (IM)
drives fed by a four-switch three-phase inverter (FSTPI). The introduced strategy is based on …

Comprehensive modeling and experimental testing of fault detection and management of a nonredundant fault-tolerant VSI

C Cecati, AO Di Tommaso, F Genduso… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper presents an investigation and a comprehensive analysis on fault operations in a
conventional three-phase voltage source inverter. After an introductory section dealing with …

A comprehensive investigation of four-switch three-phase voltage source inverter based on double Fourier integral analysis

R Wang, J Zhao, Y Liu - IEEE transactions on power electronics, 2011 - ieeexplore.ieee.org
This paper presents a comprehensive analytical investigation of the four-switch three-phase
(B4) voltage source inverter. The double Fourier integral analysis is used as an analytical …

A performance investigation of a four-switch three-phase inverter-fed IM drives at low speeds using fuzzy logic and PI controllers

MS Zaky, MK Metwaly - IEEE Transactions on Power …, 2016 - ieeexplore.ieee.org
This paper presents a speed controller using a fuzzy-logic controller (FLC) for indirect field-
oriented control (IFOC) of induction motor (IM) drives fed by a four-switch three-phase …

A three-phase high-frequency semicontrolled rectifier for PM WECS

DS Oliveira, MM Reis, CEA Silva… - … on Power Electronics, 2009 - ieeexplore.ieee.org
This paper proposes the use of a three-phase high-frequency semicontrolled rectifier for
wind energy conversion systems based on permanent magnet generators. The main …

Remedial strategies of T-NPC three-level asymmetric six-phase PMSM drives based on SVM-DTC

X Wang, Z Wang, M Cheng, Y Hu - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, novel remedial direct torque control (DTC) schemes are proposed for open-
circuit faults in T-type neutral-point-clam** (T-NPC) three-level asymmetric six-phase …