Application of UHF sensors in power system equipment for partial discharge detection: A review
Condition monitoring of an operating apparatus is essential for lifespan assessment and
maintenance planning in a power system. Electrical insulation is a critical aspect to be …
maintenance planning in a power system. Electrical insulation is a critical aspect to be …
Survey of different sensors employed for the power transformer monitoring
M Hamed Samimi… - … Science, Measurement & …, 2020 - Wiley Online Library
The importance of the continuous service of power transformers and their role in the
reliability of the power delivery has resulted in the need for various monitoring systems …
reliability of the power delivery has resulted in the need for various monitoring systems …
Partial discharge detection and diagnosis of transformer bushing based on UHF method
J Jiang, J Chen, J Li, X Yang, Y Bie… - IEEE Sensors …, 2021 - ieeexplore.ieee.org
Bushings are essential components in a power transformer where incipient partial discharge
(PD) activities and its detection and diagnosis cannot be ignorant. In this paper, an oil …
(PD) activities and its detection and diagnosis cannot be ignorant. In this paper, an oil …
Modeling of high-frequency current transformer based partial discharge detection in high-voltage cables
Partial discharge (PD) testing of high-voltage (HV) cables and cable accessories has been
implemented predominantly using high-frequency current transformers (HFCTs) as PD …
implemented predominantly using high-frequency current transformers (HFCTs) as PD …
Design and development of a bio-inspired UHF sensor for partial discharge detection in power transformers
In this paper, the design and development of a bio-inspired UHF sensor for partial discharge
detection in power transformers is presented. The UHF sensor was developed for external …
detection in power transformers is presented. The UHF sensor was developed for external …
On the electromagnetic wave behavior due to partial discharge in gas insulated switchgears: State-of-art review
The rapid growth of gas insulated switchgears as a compact, efficient, and reliable device
has recently been given great attention. Albeit gas insulated switchgears can seldom suffer …
has recently been given great attention. Albeit gas insulated switchgears can seldom suffer …
Monitoring and optimizing the state of pollution of high voltage insulators using wireless sensor network based convolutional neural network
In this paper, a wireless sensor network (WSN) is combined with Convolutional Neural
Network (CNN) forming a hybrid framework to detect the pollution state in high voltage …
Network (CNN) forming a hybrid framework to detect the pollution state in high voltage …
A compact log periodic planar dipole UHF array sensor for partial discharge measurements
A compact log periodic planar dipole UHF array antenna from 500 MHz to 2.2 GHz for partial
discharge measurement in power transformers is presented in this paper. The compactness …
discharge measurement in power transformers is presented in this paper. The compactness …
PD signal propagation in GIS: Ultra-high frequency detection-based modeling
Gas-insulated switchgears (GIS) have become essential parts of electrical power
substations due to the associated merits of these capital assets. Although such resilient …
substations due to the associated merits of these capital assets. Although such resilient …
Cable insulation fault identification using partial discharge patterns analysis
This study deals with internal defects existing or occurs in cable insulation due to stress over
its operation. The most popular tool for identifying and assessing insulation-based flaws is …
its operation. The most popular tool for identifying and assessing insulation-based flaws is …