Study of dual open ended coaxial sensor system for calculation of phase using two magnitudes
A dual open ended coaxial sensor system to determine complex permittivity was studied in
detail. This paper focuses on determination of a reflection coefficient phase from two …
detail. This paper focuses on determination of a reflection coefficient phase from two …
Measurement of permitivity of biological tissues from 300 MHZ to 3 GHz using an open-ended coaxial line
FG González, MB Miralles, DD Yero… - Revista Científica de …, 2018 - dialnet.unirioja.es
A comparative numerical study of three probe types with the same radial dimensions, three
probe models, and five reference materials is presented for six biological tissues: liver …
probe models, and five reference materials is presented for six biological tissues: liver …
Complex permittivity logging tool excited by transient signal for MWD/LWD
B Wang, K Li, F Kong, S Sheng - Progress In Electromagnetics Research M, 2013 - jpier.org
This paper proposes a new logging while drilling (LWD) method to evaluate rock moisture
content and reservoir hydrocarbon saturation. Transient signal with broadband spectrum …
content and reservoir hydrocarbon saturation. Transient signal with broadband spectrum …
Ultra-wideband and Off-optimised Five-Port Reflectometer using Power Splitters
This paper presents an ultra-wideband (UWB) and off-optimised Five-Port Reflectometer
(FPR) configured by power splitters. The proposed non-multi-state FPR is characterised and …
(FPR) configured by power splitters. The proposed non-multi-state FPR is characterised and …
Characterisation and Modelling of Microwave Open-Ended Coaxial Sensor for In Vivo Non-invasive Glucose Content Measurements
Diabetes is one of the world-leading lethal diseases that have no cure, but it is manageable
to prevent further deterioration. The in vivo non-invasive glucose monitoring method can be …
to prevent further deterioration. The in vivo non-invasive glucose monitoring method can be …
Dielectric measurement using planar and curved microstrip line
In this paper, a microwave transmission line sensor is investigated and used for bulk liquid
permittivity measurement. A microstrip type transmission line is designed and analysed for a …
permittivity measurement. A microstrip type transmission line is designed and analysed for a …
Investigation of a Conductivity Logging Tool Based on Single Coil Impedance Measurement Using FDTD Method
S Sheng, K Li, F Kong, B Wang - Progress in Electromagnetics Research M, 2014 - jpier.org
Eddy current test has been widely used in many fields because of its simplicity and
robustness. In this paper, numerical simulations based on the finite-difference time-domain …
robustness. In this paper, numerical simulations based on the finite-difference time-domain …
[HTML][HTML] Medición de la permitividad de los tejidos biológicos desde 300 MHz hasta 3 GHz usando una línea coaxial abierta en un extremo
F Gilart, M Bueno, D Deas, R Vázquez - … Electrónica, Automática y …, 2018 - scielo.sld.cu
Para seis tejidos biológicos-hígado, músculo, riñón, corazón, sangre y grasa-se presenta un
estudio numérico comparativo de tres tipos de sonda con las mismas dimensiones radiales …
estudio numérico comparativo de tres tipos de sonda con las mismas dimensiones radiales …