Quality assurance for clinical high intensity focused ultrasound fields

J Civale, I Rivens, G ter Haar - International Journal of …, 2015 - Taylor & Francis
As the use of HIFU in the clinic becomes more widespread there is an ever increasing need
to standardise quality assurance protocols, an important step in facilitating the wider …

Physico-Mechanical Metrology: Part IV: Force, Pressure and Flow Metrology

S Yadav, SSK Titus, R Kumar, I Elizabeth… - Metrology for Inclusive …, 2020 - Springer
Accurate and precise measurements of physico-mechanical quantities, such as Force,
Torque, Hardness, Pressure, Vacuum and Fluid Flow are extremely important and crucial in …

Development of high ultrasonic power measurement technique by calorimetric method using water as heating elements for high ultrasonic power standard

T Uchida, T Kikuchi, M Yoshioka, Y Matsuda… - Acoustical Science …, 2015 - jstage.jst.go.jp
We have started to develop an accurate measurement technique by a calorimetric method
with the aim of setting the national measurement standards for high ultrasonic power. In a …

Relationship between acoustic power and acoustic radiation force on absorbing and reflecting targets for spherically focusing radiators

P Gélat, A Shaw - Ultrasound in medicine & biology, 2015 - Elsevier
Total acoustic output power is an important parameter required by standards for most
ultrasonic medical equipment including high-intensity focused ultrasound (HIFU) systems …

Improved and automated primary ultrasonic power measurement setup at CSIR-NPL, India

PK Dubey, A Jain, S Singh - Mapan, 2015 - Springer
Ultrasonic power generated by an ultrasonic transducer must be measured and declared for
the ultimate safety of patients. According to IEC-61161 radiation force balance is …

Calibration and Quality Assurance for High Intensity Focused Ultrasound Fields

I Rivens, J Civale - Image-guided Focused Ultrasound Therapy - taylorfrancis.com
This chapter addresses the need for high-intensity focused ultrasound (HIFU or FUS)
calibration and/or quality assurance (QA), the state of the art (in terms of available …

High resolution vertical movement system for transducer and target separation in primary ultrasonic power measurement setup

PK Dubey, S Singh - Measurement, 2015 - Elsevier
Radiation force balance approach is universally adopted and most widely used primary
calibration method for total acoustic power radiated by an ultrasonic transducer. In this …

State Primary Standard of Ultrasound Power Unit in Water GET 169-2019

АМ Еnyakov, SI Kuznetsov, GS Lukin - Measurement Techniques, 2020 - Springer
The results of works on the improvement of the State Primary Standard of an ultrasound
power unit in water GET 169-2005 are presented in this paper. As a result of the inclusion of …

Государственный первичный эталон единицы мощности ультразвука в воде ГЭТ 169-2019

АМ Еняков, СИ Кузнецов, ГС Лукин - Измерительная техника, 2020 - elibrary.ru
Приведены результаты работ по совершенствованию Государственного первичного
эталона единицы мощности ультразвука в воде ГЭТ 169-2005. В результате включения …

[PDF][PDF] ULTRASONICS METROLOGY III. THE DEVELOPMENT OF THERMAL METHODS FOR ULTRASOUND MEASUREMENT

I EARLY - mpijournal.org
The temperature rise that occurs when energy from the transmission of ultrasound is
absorbed in the propagation medium has been used to quantify exposure from the earliest …