Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Silent zero TE MR neuroimaging: current state-of-the-art and future directions
Abstract Magnetic Resonance Imaging (MRI) scanners produce loud acoustic noise
originating from vibrational Lorentz forces induced by rapidly changing currents in the …
originating from vibrational Lorentz forces induced by rapidly changing currents in the …
Acoustic noise and magnetic resonance imaging: a narrative/descriptive review
MJ McJury - Journal of Magnetic Resonance Imaging, 2022 - Wiley Online Library
Magnetic resonance imaging generates unwanted acoustic noise. This review describes the
work characterizing the acoustic noise, and the various solutions to control and attenuate the …
work characterizing the acoustic noise, and the various solutions to control and attenuate the …
Zero-TE MRI: principles and applications in the head and neck
Zero echo-time (ZTE) MRI is a novel imaging technique that utilizes ultrafast readouts to
capture signal from short-T2 tissues. Additional sequence advantages include rapid imaging …
capture signal from short-T2 tissues. Additional sequence advantages include rapid imaging …
Synthetic CT in musculoskeletal disorders: a systematic review
Repeated computed tomography (CT) examinations increase patients' ionizing radiation
exposure and health costs, making an alternative method desirable. Cortical and trabecular …
exposure and health costs, making an alternative method desirable. Cortical and trabecular …
Motion corrected silent ZTE neuroimaging
Purpose To develop self‐navigated motion correction for 3D silent zero echo time (ZTE)
based neuroimaging and characterize its performance for different types of head motion …
based neuroimaging and characterize its performance for different types of head motion …
Three‐dimensional reduced field‐of‐view imaging (3D‐rFOVI)
Purpose This study aimed at develo** a 3D reduced field‐of‐view imaging (3D‐rFOVI)
technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve …
technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve …
Silent myelin-weighted magnetic resonance imaging
Background: Inhomogeneous Magnetization Transfer (ihMT) is an emerging, uniquely
myelin-specific magnetic resonance imaging (MRI) contrast. Current ihMT acquisitions …
myelin-specific magnetic resonance imaging (MRI) contrast. Current ihMT acquisitions …
Effect of acoustic noise reduction technology on image quality: a multivendor study
T Yamashiro, Y Takatsu, K Morita, M Nakamura… - … Physics and Technology, 2023 - Springer
The purpose of this study was to clarify the appropriate use of a combination of pulse
sequences and acoustic noise reduction technology in general-purpose brain magnetic …
sequences and acoustic noise reduction technology in general-purpose brain magnetic …
Volumetric and multispectral DWI near metallic implants using a non‐linear phase Carr‐Purcell‐Meiboom‐Gill diffusion preparation
PK Lee, D Yoon, JK Sandberg… - Magnetic …, 2022 - Wiley Online Library
Purpose DWI near metal implants has not been widely explored due to substantial
challenges associated with through‐slice and in‐plane distortions, the increased encoding …
challenges associated with through‐slice and in‐plane distortions, the increased encoding …
Near‐silent and distortion‐free diffusion MRI in pediatric musculoskeletal disorders: Comparison with Echo planar imaging diffusion
JK Sandberg, VA Young, AB Syed… - Journal of Magnetic …, 2021 - Wiley Online Library
Background Diffusion‐weighted imaging (DWI) is common for evaluating pediatric
musculoskeletal lesions, but suffers from geometric distortion and intense acoustic noise …
musculoskeletal lesions, but suffers from geometric distortion and intense acoustic noise …